Fabric OS 6.2.2b fixes, Table 12 Fabric OS 6.2.2a closed defects
View all HP Brocade 8/12c manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 45 highlights
Table 12 Fabric OS 6.2.2a closed defects Closed defect summary Solution After a target port bounce, the FC FastWrite host cannot recognize the target due to a cam setup problem on the backend port used by FC FastWrite. Fixed in Fabric OS 6.2.2a After upgrading to Fabric OS 6.2.x, the 400 MP Router or Multiprotocol Fixed in Fabric OS 6.2.2a Router blade detects a credit problem on virtual channel 0, causing a frame drop on FCIP and FC FastWrite, and the host is unable to recognize the target. While running Fabric OS 6.2.2, the switch can panic after executing a Fixed in Fabric OS 6.2.2a fcplunquery or iscsicfg CLI command for the target entity on HP StorageWorks iSCSI Director Blade. An FCPD termination occurs if a PRLI or Report LUN query times out during fcplunquery/iscsicfg command and the LOGO response is missing a message queue required for processing, resulting in a switch panic. Fabric class areas→Zoning Changes in fwconfigure does not function correctly. Zone changes are not recorded in the FW module, resulting in threshold alarms not being raised as appropriate. Fixed in Fabric OS 6.2.2a After using the ipaddrset -cp command to set a CP blade or director switch host name, the standby CP incorrectly displays the CP host name instead of the chassis host name. For the change to take effect, after upgrading the firmware, the user must logout, and then log back in. Fixed in Fabric OS 6.2.2a During reboot, HP StorageWorks D2D Backup System device sends the explicit logout; however, the switch does not clean up the route properly, resulting in the hosts being unable to detect the tape devices. Fixed in Fabric OS 6.2.2a Username/password authentication can fail when using Microsoft Active Fixed in Fabric OS 6.2.2a Directory (LDAP) from Server 2008 for authentication. Users can experience problems after upgrade from a Microsoft Windows host using older versions of the LDAP protocol for authentications. After using the snmpconfig -set snmpv command to set SNMPv3, the Fixed in Fabric OS 6.2.2a switch configdownload command failed with the following message: snmp.snmpv3Usm.0.usmPrivProtocol:6 Invalid Value. If you set fwsettocustom, the HP StorageWorks DC SAN Backbone Fixed in Fabric OS 6.2.2a Director does not output FW-1003/FW-1004 after an hafailover or reboot, and you will not be notified about temperature over threshold events. The systemverification and portloopbacktest diagnostic tests report marginal Fixed in Fabric OS 6.2.2a blade failures on an HP StorageWorks DC SAN Director, but after the tests are complete, Fabric Watch reports switch is healthy. Fabric OS 6.2.2b fixes Table 13 (page 45) lists defects closed in the Fabric OS 6.2.2b firmware release. Table 13 Fabric OS 6.2.2b closed defects Closed defect summary Solution After upgrading EFCM to 9.7.4 and HP StorageWorks 4/256 SAN director Fixed in Fabric OS 6.2.2b to 6.2.0x, customer is unable to discover switches due to performance of SNMP get for connUnitLinkTable being reduced in 6.2.x. Excessive internal messages cause a RASLOG flood condition and a Fixed in Fabric OS 6.2.2b weblinkerfcg message appears on FCIP switches in the fabric (HP StorageWorks 1606 Extension SAN Switch and Multiprotocol Extension Blade). This can lead to other important RASLOG messages being lost. This issue has no functional impact and occurs on platforms not running ipsd (IP Security Daemon). Fabric OS 6.2.2b fixes 45