HP Brocade 8/12c HP Fabric OS 6.2.2f Release Notes (5697-1756, February 2012) - Page 43
The 4Gb SAN Switch for HP c-Class BladeSystem AG may login to DC, SAN Director with wrong PWWN.
View all HP Brocade 8/12c manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 43 highlights
Table 11 Fabric OS 6.2.2 closed defects (continued) Closed defect summary Solution Fabric Watch SFP messages get logged after upgrade to Fabric OS 6.1.1b, Fixed in Fabric OS 6.2.2 due to I2C read values of 0xff and I2C NACK error case not being properly handled. Switch gets nsd panic when third-party switch in interopmode 3 and Fabric Fixed in Fabric OS 6.2.2 OS 6.2 sends invalid frames. Server does not see some devices on shared primary ports connected to Fixed in Fabric OS 6.2.2 48 port blades using domain/port session based zoning. The configdownload command does not load tstimezone info after changing tzh and tzm in the config.txt file to new values. Fixed in Fabric OS 6.2.2 Workaround prior to update: Set up tstimezone through CLI. Transient detected error on internal link caused 8-Gb blade to be faulted with reason=5 or 4. Fixed in Fabric OS 6.2.2 Workaround prior to update: Use slotpoweroff and slotpoweron to clear the fault. When running the Zone admin, with 48 port blade where there is port Fixed in Fabric OS 6.2.2 address sharing, devices show up on the wrong port. When port index and port address of the given port is different, end device will be seen connected to a different port (U port) than the original one (F_Port). HP StorageWorks DC Switch Encryption blade comes up faulty after firmwaredownload -sf and reboot of both CPs at the same time. Fixed in Fabric OS 6.2.2 Workaround prior to update: Reseat the blade. After upgrade to Fabric OS 6.x, rsh using user credential gets ifmodeshow eth0: ioctl (ETHTOOL_GSET) failed error in response to ifmodeshow command. Telnet and rsh with root credential work fine. Fixed in Fabric OS 6.2.2 Workaround prior to update: Set suid permissions for ethmode: chmod +s /fabos/libexec/ethmode Backup job stopped for an extended period of time when running through Fixed in Fabric OS 6.2.2 HP StorageWorks Encryption switch or encryption blade after bouncing 1 of the 2 connected ISLs. The 4Gb SAN Switch for HP c-Class BladeSystem AG may login to DC SAN Director with wrong PWWN. Fixed in Fabric OS 6.2.2 Workaround prior to update: Reboot AG. During director switch initialization from power on, reboot, or hafailover, Fixed in Fabric OS 6.2.2 daemons fail to load causing switch to auto reboot and ffdc HAM-1008 and HAM-1007 errors are observed. When running a third-party host scan, the http daemon (weblinker.fcg) Fixed in Fabric OS 6.2.2 terminates and restarts several times, causing a temporary management service interruption. In Fabric OS 6.2, OID for connUnitType no longer returns the correct Fixed in Fabric OS 6.2.2 access gateway mode status after upgrade from Fabric OS 6.1.1d to 6.2.0f. Fabric binding does not work in 239 domain mode in Interopmode 3 with Fixed in Fabric OS 6.2.2 FCR on 8Gb switches. EX port rejects it. Fabric Watch sometimes logs messages with values above 100%. Most Fixed in Fabric OS 6.2.2 likely occurs during first Fabric Watch polling cycle after slotstatsclear command is issued. The following message may display on the console while firmware commit Fixed in Fabric OS 6.2.2 is in progress: ssnGet: Unable to get WWN info.sw=0 rc=-5. While doing a disruptive CP reboot on a director class switch (reboot active Fixed in Fabric OS 6.2.2 CP when no standby CP is present), if simultaneous fabric update causes Fabric OS 6.2.2 fixes 43