HP Brocade 8/12c HP Fabric OS 6.2.2f Release Notes (5697-1756, February 2012) - Page 49
Fabric OS 6.2.2e fixes, Table 16 Fabric OS 6.2.2e closed defects
View all HP Brocade 8/12c manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 49 highlights
Table 16 Fabric OS 6.2.2e closed defects (continued) Closed defect summary Solution Switch, HP 8/8 (8)-ports Enabled SAN, HP 8/24 Base 16-ports Enabled SAN Switch Switch, HP 8/40 Base 24-ports Enabled SAN Switch, and the HP 8/40 Power Pack+ 24-ports SAN Switch. Access Gateway is not displayed by the DCFM client Fixed in Fabric OS 6.2.2e. when utilizing an EOS seed switch. When more than one RPC connection is established simultaneously on a switch with busy management applications, a race condition may cause multiple connections to free a shared object and trigger rpcd panic. Fixed in Fabric OS 6.2.2e. After performing a LOGO following a firmware Fixed in Fabric OS 6.2.2e. download the switch route is not properly established. The host cannot see the target because the PLOGI Accept from the HBA is dropped by the switch. The LED for online trunked F-Ports goes from a steady Fixed in Fabric OS 6.2.2e. green to off after a code upgrade or hareboot/hafailover. A switch panic occurs when a management Fixed in Fabric OS 6.2.2e. application polls for Access Gateway device information or when agshow command is executed. WARNING raslog messages of "[CDR-1003]" unnecessarily generate the call home function. Fixed in Fabric OS 6.2.2e. SNMPmibwalk only shows MIB connUnitPortEntries Fixed in Fabric OS 6.2.2e. for ports that have SFPs installed. Fabric OS 6.2.2f fixes Table 17 (page 49) lists defects closed in the Fabric OS 6.2.2f firmware release. Table 17 Fabric OS 6.2.2e closed defects Closed defect summary Solution A device may not be accessible after FCIP links have Fixed in Fabric OS 6.2.2f. bounced multiple times in a Fibre Channel Backbone fabric because the Fibre Channel Router is not properly translating all SID/DIDs. Frames with the same SID/DID were sent to the device after a proxy translation failed in a backbone to edge FCR configuration. IDLE not being sent after a NOS causes an issue and Fixed in Fabric OS 6.2.2f. one side the ISL becomes a G_Port, while the peer remains an E_Port. A host is unable to link up to an 8 Gb FC port when Fixed in Fabric OS 6.2.2f. the 8 Gb-capable port is configured at a fixed 4 or 8 Gb speed and the remote port is configured at auto negotiation speed, and there is only one port connected to the remote switch. An F_Port may become stuck in a disabled state and Fixed in Fabric OS 6.2.2f. report a raslog: [AG-1005] error after an Acesss Gateway reboot. FAN frames are not being sent by the switch to loop Fixed in Fabric OS 6.2.2f. devices after LIP when fcAL.fanFrameDisable is set to Fabric OS 6.2.2f fixes 49