fmConfig, serDesTuneMode, SYNOPSIS, DESCRIPTION, OPERANDS
![]() |
View all HP Brocade 8/12c manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 52 highlights
5 fmConfig fmConfig This command has been reclassified as an Advanced Performance Monitor (APM) command. It is no longer displayed with the fwHelp command; it is now displayed under perfHelp. Permissions for the operator role have changed. Users with the operator role do not have permission to execute following commands: • fmConfig --create • fmconfig --change • fmconfig --addmonitor • fmconfig --delmonitor • fmconfig --delete • fmconfig --save • fmconfig --clear Users with the operator role are allowed to execute following commands: • fmconfig --show • fmconfig --help serDesTuneMode This command has been enhanced with new operands to support an automated tuning process to fix CRC errors. The man page has been updated as follows; only the additions are shown below. NAME SYNOPSIS Configures and displays SerDes tuning parameters. serdestunemode --autoenable serdestunemode --autodisable serdestunemode --autoreset serdestunemode --autoshow DESCRIPTION OPERANDS Use this command to configure and display SerDes values on the Brocade FC8-16 and to control tuning optimization of backend links for all Brocade FC8-xx blades. When used with the --autoset, --autodisable, --autoreset and --autoshow options, this command configures tuning optimization for backend SerDes errors. SerDes tuning optimization is indicated when you receive RASLog errors of type C2-5825 indicating a CRC error with a good EOF. Brocade highly recommends that you contact your service provider if you encounter such errors. If the error appears to be an isolated incident, you may enable auto SerDes tuning for a short period of time (24-48 hours) to see if this resolves the problem. Then disable the function to reduce the risk of resetting register values unnecessarily if single occurrence errors are encountered. If the errors persist contact your service provider. --autoset --autodisable --autoreset --autoshow Enables SerDes tuning optimization on all backend ports. Disables further tuning optimization but retains all current tuning values identified by the algorithm. Disables further tuning optimization and resets all tuning values back to their default values. If SerDes tune mode or was set, the co figuration is restored. Displays whether SerDes tuning optimization is enabled or disabled. 40 Fabric OS Documentation Updates 53-1002063-09
![](/manual_guide/products/hewlettpackard-storefabric-sn6500b-brocade-fabric-os-documentation-updates-supporting-fabric-os-v64x-53100206309-2012-1feb673/52.png)