HP Brocade 8/12c Brocade Fabric OS Documentation Updates - Supporting Fabric O - Page 55

Fabric OS Message Reference, In this Documentation updates for Fabric OS v6.4.0 and later

Page 55 highlights

EA DRAFT: BROCADE CONFIDENTIAL Fabric OS Message Reference Chapter 6 In this chapter Replace and update the chapters as described in the following sections: •Documentation updates for Fabric OS v6.4.0 and later 43 •Chapter 12, CDR System Messages 43 •Chapter 31, FCOE System Messages 44 •Chapter 57, KAC System Messages 45 Documentation updates for Fabric OS v6.4.0 and later The updates in this chapter are for the Fabric OS Message Reference Supporting Fabric OS v6.4.0 (53-1001767-01), originally published in March 2010. NOTE The updates are arranged by the chapter names as they appear in the original document. Chapter 12, CDR System Messages Include the following messages in the chapter, CDR System Messages on page 88. CDR-1007 Message , [CDR-1007], ,, WARNING, , S,C: Internal link errors have been reported, no hardware faults identified, continuing to monitor for errors: flt1:, flt2: thresh1:0x. Probable Cause Indicates some errors found in hardware that may or may not impact data traffic. Recommended No action is required. Action Severity WARNING CDR-1008 Message , [CDR-1008], ,, WARNING, , S,C: HW ASIC Chip warning Level 1 type = 0x. Fabric OS Documentation Updates 43 53-1002063-09

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70

Fabric OS Documentation Updates
43
53-1002063-09
EA DRAFT: BROCADE CONFIDENTIAL
Chapter
6
Fabric OS Message Reference
In this chapter
Replace and update the chapters as described in the following sections:
Documentation updates for Fabric OS v6.4.0 and later. . . . . . . . . . . . . . . .
43
Chapter 12, CDR System Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
43
Chapter 31, FCOE System Messages. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
44
Chapter 57, KAC System Messages. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
45
Documentation updates for Fabric OS v6.4.0 and later
The updates in this chapter are for the
Fabric OS Message Reference
Supporting Fabric OS v6.4.0
(53-1001767-01), originally published in March 2010.
NOTE
The updates are arranged by the chapter names as they appear in the original document.
Chapter 12, CDR System Messages
Include the following messages in the chapter, CDR System Messages on page 88.
CDR-1007
Message
<timestamp>, [CDR-1007], <sequence-number>,, WARNING, <system-name>, S<slot
number>,C<chip index>: Internal link errors have been reported, no hardware faults
identified, continuing to monitor for errors: flt1:<fault1_cnt>,
flt2:<fault2_cnt> thresh1:0x<threshold_used>.
Probable Cause
Indicates some errors found in hardware that may or may not impact data traffic.
Recommended
Action
No action is required.
Severity
WARNING
CDR-1008
Message
<timestamp>, [CDR-1008], <sequence-number>,, WARNING, <system-name>, S<slot
number>,C<chip index>: HW ASIC Chip warning Level 1 type = 0x<chip error type>.