HP Brocade 8/12c Brocade Fabric OS Documentation Updates - Supporting Fabric O - Page 56
FCOE System Messages, CDR-1009, FCOE-1020
![]() |
View all HP Brocade 8/12c manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 56 highlights
6 CDR-1009 EA DRAFT: BROCADE CONFIDENTIAL Probable Cause Indicates an internal error in the ASIC hardware that may or may not degrade data traffic. Recommended Whenever this error occurs, restart the system at the next maintenance window. Action Severity WARNING CDR-1009 Message , [CDR-1009], ,, WARNING, , S,C: HW ASIC Chip warning Level 2 type = 0x. Probable Cause Indicates an internal error in the ASIC hardware that may or may not degrade data traffic. Recommended Whenever this error occurs, restart the system at the next maintenance window. Action Severity WARNING CDR-1010 Message , [CDR-1010], ,, CRITICAL, , S,C: Internal monitoring of faults has identified suspect hardware, blade may need to be reset or replaced: fault1:, fault2: thresh2:0x. Probable Cause Indicates above normal errors observed in hardware that may or may not impact data traffic. Recommended Whenever this error is observed persistently, power cycle the faulted blade. If the problem persists, Action replace the blade. Severity CRITICAL Chapter 31, FCOE System Messages Include the following message in the chapter, FCOE System Messages on page 205. FCOE-1020 Message , [FCOE-1020], ,, INFO, , Login rejected by FC stack. Probable Cause Indicates a FLOGI was sent to the FC stack by the FCoE driver but login was rejected by FC stack. Recommended No action is required. Action Severity INFO 44 Fabric OS Documentation Updates 53-1002063-09
![](/manual_guide/products/hewlettpackard-storefabric-sn6500b-brocade-fabric-os-documentation-updates-supporting-fabric-os-v64x-53100206309-2012-1feb673/56.png)