4. Tilt the LED panel away from the front of the storage blade until the retaining clips are clear of the back of the LED panel, and then remove the LED panel. To replace the component, reverse the removal procedure. System board WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the internal system components to cool before touching them. CAUTION: To prevent damage to electrical components, properly ground the server blade before beginning any installation procedure. Improper grounding can cause ESD. CAUTION: Do not operate the storage blade with the access panel open or removed. Operating the storage blade in this manner results in improper airflow and improper cooling that can lead to thermal damage. To remove the component: 1. Back up all data on the storage blade. 2. Power down the partner server blade (on page 21). 3. Remove the storage blade (on page 21). 4. Remove all hard drives ("Remove the hard drives" on page 22). 5. Remove the access panel (on page 23). 6. Remove the FBWC capacitor pack ("FBWC capacitor pack" on page 26). 7. Remove the FBWC module ("FBWC module" on page 27). Removal and replacement procedures 30

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47

Removal and replacement procedures
30
4.
Tilt the LED panel away from the front of the storage blade until the retaining clips are clear of the
back of the LED panel, and then remove the LED panel.
To replace the component, reverse the removal procedure.
System board
WARNING:
To reduce the risk of personal injury from hot surfaces, allow the drives and the
internal system components to cool before touching them.
CAUTION:
To prevent damage to electrical components, properly ground the server blade
before beginning any installation procedure. Improper grounding can cause ESD.
CAUTION:
Do not operate the storage blade with the access panel open or removed.
Operating the storage blade in this manner results in improper airflow and improper cooling
that can lead to thermal damage.
To remove the component:
1.
Back up all data on the storage blade.
2.
Power down the partner server blade (on page
21
).
3.
Remove the storage blade (on page
21
).
4.
Remove all hard drives ("
Remove the hard drives
" on page
22
).
5.
Remove the access panel (on page
23
).
6.
Remove the FBWC capacitor pack ("
FBWC capacitor pack
" on page
26
).
7.
Remove the FBWC module ("
FBWC module
" on page
27
).