HP D2200sb HP StorageWorks D2200sb PCIe Storage Blade Maintenance and Service - Page 33

Hard drive drawer

Page 33 highlights

12. Remove the system board. To replace the component, reverse the removal procedure. After you replace the system board, you must re-enter the product identification and serial number in the Onboard Administrator using the command line. The Onboard Administrator CLI can be accessed locally from a laptop connected to a serial port connector on the rear of the Onboard Administrator module or remotely through a Telnet or SSH session. To enter the product information: 1. Obtain the serial number from the product information tag. 2. Access the Onboard Administrator CLI. 3. Issue the following command in the CLI: SET DEVICE SERIAL_NUMBER BLADE Hard drive drawer WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the internal system components to cool before touching them. CAUTION: To prevent damage to electrical components, properly ground the storage blade before beginning any installation procedure. Improper grounding can cause ESD. CAUTION: Do not operate the storage blade with the access panel open or removed. Operating the storage blade in this manner results in improper airflow and improper cooling that can lead to thermal damage. To remove the component: 1. Back up all data on the storage blade. 2. Power down the partner server blade (on page 21). 3. Remove the storage blade (on page 21). 4. Remove all hard drives ("Hard drive" on page 25). Removal and replacement procedures 33

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47

Removal and replacement procedures
33
12.
Remove the system board.
To replace the component, reverse the removal procedure.
After you replace the system board, you must re-enter the product identification and serial number in the
Onboard Administrator using the command line. The Onboard Administrator CLI can be accessed locally
from a laptop connected to a serial port connector on the rear of the Onboard Administrator module or
remotely through a Telnet or SSH session.
To enter the product information:
1.
Obtain the serial number from the product information tag.
2.
Access the Onboard Administrator CLI.
3.
Issue the following command in the CLI:
SET DEVICE SERIAL_NUMBER BLADE <bay number> <serial number>
Hard drive drawer
WARNING:
To reduce the risk of personal injury from hot surfaces, allow the drives and the
internal system components to cool before touching them.
CAUTION:
To prevent damage to electrical components, properly ground the storage blade
before beginning any installation procedure. Improper grounding can cause ESD.
CAUTION:
Do not operate the storage blade with the access panel open or removed.
Operating the storage blade in this manner results in improper airflow and improper cooling
that can lead to thermal damage.
To remove the component:
1.
Back up all data on the storage blade.
2.
Power down the partner server blade (on page
21
).
3.
Remove the storage blade (on page
21
).
4.
Remove all hard drives ("
Hard drive
" on page
25
).