Front panel LEDs

Page 40 highlights

Front panel LEDs Item Description Status 1 UID LED Blue = Identified Off = Not identified 2 System health LED* Green = Normal operation Flashing amber = No partner blade, or not yet recognized Solid amber = Degraded condition Flashing red = System critical Red = Hard drive over-temperature triggered shutdown 3 Hard drive fault LED Off = Normal operation Solid amber = Drive failed Flashing amber = Predictive failure 4 Hard drive activity Solid green = Drive installed LED Flashing green = Drive activity established Flashing green (slow) = Drive rebuilding 5 Drawer temp LED Off = Drawer is closed, or thermal shutdown has occurred. Flashing amber (1 per 5 seconds) = Drawer is open. Flashing amber (2 per second) = Hard drives have reached near-critical temperatures. * The system health LED flashes amber when the storage blade establishes a connection with the enclosure, either immediately after installation or when the storage blade is removed and reinstalled. If the LED continues to flash for more than 2 minutes, there is a fault. Make sure the partner server blade is powered down before the storage blade is installed. Component identification 40

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47

Component identification 40
Front panel LEDs
Item
Description
Status
1
UID LED
Blue = Identified
Off = Not identified
2
System health LED*
Green = Normal operation
Flashing amber = No partner blade,
or not yet recognized
Solid amber = Degraded condition
Flashing red = System critical
Red = Hard drive over-temperature
triggered shutdown
3
Hard drive fault LED
Off = Normal operation
Solid amber = Drive failed
Flashing amber = Predictive failure
4
Hard drive activity
LED
Solid green = Drive installed
Flashing green = Drive activity
established
Flashing green (slow) = Drive
rebuilding
5
Drawer temp LED
Off = Drawer is closed, or thermal
shutdown has occurred.
Flashing amber (1 per 5 seconds) =
Drawer is open.
Flashing amber (2 per second) = Hard
drives have reached near-critical
temperatures.
* The system health LED flashes amber when the storage blade establishes a connection with the enclosure, either
immediately after installation or when the storage blade is removed and reinstalled. If the LED continues to flash for
more than 2 minutes, there is a fault. Make sure the partner server blade is powered down before the storage blade