IP address of the HP StorageWorks D2D Backup System

Page 45 highlights

2. Configure the Solaris host to discover available iSCSI targets as follows, where x.x.x.x is the IP address of the HP StorageWorks D2D Backup System: # iscsiadm add discovery-address x.x.x.x:3260 # iscsiadm list discovery-address Discovery Address: x.x.x.x:3260 # iscsiadm modify discovery -t enable # iscsiadm list discovery Discovery: Static: disabled Send Targets: enabled iSNS: disabled 3. List the configured iSCSI target devices as follows: # iscsiadm list target Target: iqn.198603.com.hp:storage.d2d.cr203f18f4.01a9754150ae013a.library1.robotics Alias: D2D.CR203F18F4.Library1.Robotics TPGT: 1 ISID: 4000002a0000 Connections: 1 Target: iqn.1986-03.com.hp:storage.d2d.cr203f18f4.7e0cdac23ab4eab1 .library1.drive1 Alias: D2D.CR203F18F4.Library1.Drive1 TPGT: 1 ISID: 4000002a0000 Connections: 1 In this example the two target iSCSI Qualified Names are: iqn.1986-03.com.hp:storage.d2d.cr203f18f4.01a9754150ae013a .library1.robotics iqn.1986-03.com.hp:storage.d2d.cr203f18f4.7e0cdac23ab4eab1 .library1.drive1 NOTE: In the following commands, items in parentheses are user-defined strings. Substitute the appropriate information for , and . D2D Backup System 45

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52

2.
Configure the Solaris host to discover available iSCSI targets as follows, where
x.x.x.x
is the
IP address of the HP StorageWorks D2D Backup System:
# iscsiadm add discovery-address x.x.x.x:3260
# iscsiadm list discovery-address
Discovery Address: x.x.x.x:3260
# iscsiadm modify discovery -t enable
# iscsiadm list discovery
Discovery:
Static: disabled
Send Targets: enabled
iSNS: disabled
3.
List the configured iSCSI target devices as follows:
# iscsiadm list target
Target: iqn.1986-
03.com.hp:storage.d2d.cr203f18f4.01a9754150ae013a.library1.robotics
Alias: D2D.CR203F18F4.Library1.Robotics
TPGT: 1
ISID: 4000002a0000
Connections: 1
Target: iqn.1986-03.com.hp:storage.d2d.cr203f18f4.7e0cdac23ab4eab1
.library1.drive1
Alias: D2D.CR203F18F4.Library1.Drive1
TPGT: 1
ISID: 4000002a0000
Connections: 1
In this example the two target iSCSI Qualified Names are:
iqn.1986-03.com.hp:storage.d2d.cr203f18f4.01a9754150ae013a
.library1.robotics
iqn.1986-03.com.hp:storage.d2d.cr203f18f4.7e0cdac23ab4eab1
.library1.drive1
NOTE:
In the following commands, items in parentheses are user-defined strings. Substitute the
appropriate information for
<iqn...>
,
<chap_password>
and
<chap_username>
.
D2D Backup System