HP DL580 ProLiant DL580 Generation 4 Maintenance and Service Guide - Page 76
Miscellaneous port 85 codes
UPC - 882780616011
View all HP DL580 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 76 highlights
Miscellaneous port 85 codes To troubleshoot all other port 85 codes: IMPORTANT: Reboot the server after completing each numbered step. If the error condition continues, proceed with the next step. 1. Bring the server to base configuration by removing all components that are not required by the server to complete POST. This process can include removing all: o Expansion boards ("Removing a non-hot-plug expansion board" on page 41, "Removing a PCI-X Hot Plug expansion board" on page 42) o Processors ("Removing a processor or processor blank" on page 34), except the processor installed in socket 1 IMPORTANT: Processor socket 1 and PPM slot 1 must be populated at all times or the server does not function properly. o PPMs ("Removing a PPM" on page 37), except the PPM installed in slot 1 o DIMMs ("Removing DIMMs" on page 68), except the first bank o Hard drives ("Removing a hot-plug SAS hard drive" on page 54) o Peripheral devices 2. Install each remaining system component, rebooting between each installation to isolate any failed components. 3. Clear the system NVRAM ("System maintenance switch" on page 86). 4. Replace the system board. IMPORTANT: If replacing the system board or clearing NVRAM, you must re-enter the server serial number through RBSU ("Re-entering the server serial number and product ID" on page 48). Diagnostic tools 76