HP Designjet 230 Service Manual - Page 159
Faulty RAM SIMM.
View all HP Designjet 230 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 159 highlights
Filename selftest.c selftest.c selftest.c selftest.c selftest.c ipc.c media_load.c error.c miInterface.c Line Number Firmware A.01.00 1522 1526 1569 1573 1579 813 or 824 681 or 2403 or 2430 or 2619 536 1973 or 1997 Failure (and most frequent causes) Failure in RAM SIMM test: D RAM SIMM badly connected. D Faulty RAM SIMM. D Faulty electronics module. Failure in RAM SIMM test: D RAM SIMM badly connected D Faulty RAM SIMM D Faulty electronics module. Failure in Fibis test: D Faulty electronics module. Failure in Fibis RAM sequence test: D Faulty electronics module. Failure in Condor test: D If firmware is revision A.01.02 or earlier, then change to latest. D Faulty electronics module. The SPROC did not respond within 10 seconds: D Faulty electronics module. Bail error or YĆaxis servo error: D Carriage knocked against bail. D Faulty encoder strip. D Faulty trailing cable. D Faulty carriage. Processor error: D Faulty electronics module. Mechanical problem when the carriage attempts to position itself over the service station. Check the mechanics. C4699Ć90000 Troubleshooting 8Ć25