Cannot connect to the switch console interface remotely

Page 49 highlights

The switch fails to get its IP settings from the BOOTP server, even though by default it is configured for BOOTP Action: • The switch is not connected properly to the network. Check the cable and connections and be sure that there is network connectivity between the switch and the BOOTP server. • The BOOTP server is not available on the network or VLAN that is attached to the switch management port. Be sure that the BOOTP server is present on the network or VLAN attached to the switch. • The BOOTP server cannot offer IP settings to the switch because no IP addresses are available. Add additional IP addresses as necessary. • The switch timed out its request for IP settings. Reset the switch. The keyboard locks up when using HyperTerminal to log on to the switch through the console interface Action: Scroll lock is on. Press the Scroll Lock key on the keyboard and be sure that the scroll lock is off. Cannot connect to the switch console interface remotely using Telnet Action: • The switch IP address is not configured or correct. • From the serial console interface, be sure that the switch IP address is configured and valid on the network. • Use the correct IP address to establish the Telnet connection with the switch. • The setting allowing access to the switch using the Telnet interface is disabled. From the serial console interface, be sure that the Telnet interface is enabled. • The management network address/mask (if used) does not contain the IP address of the management station. From the serial console interface, be sure that the Management Network Address/Mask contains the IP address of the management station. Password is not accepted by the switch using the remote console interface immediately after a reboot Action: The switch is still working on network convergence. Wait up to 10 seconds for the password to be accepted. Cannot connect to the switch console interface remotely using SSH Action: Troubleshooting 49

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58

Troubleshooting 49
The switch fails to get its IP settings from the BOOTP
server, even though by default it is configured for BOOTP
Action:
The switch is not connected properly to the network. Check the cable and connections and be sure
that there is network connectivity between the switch and the BOOTP server.
The BOOTP server is not available on the network or VLAN that is attached to the switch
management port. Be sure that the BOOTP server is present on the network or VLAN attached to the
switch.
The BOOTP server cannot offer IP settings to the switch because no IP addresses are available. Add
additional IP addresses as necessary.
The switch timed out its request for IP settings. Reset the switch.
The keyboard locks up when using HyperTerminal to log
on to the switch through the console interface
Action:
Scroll lock is on. Press the Scroll Lock key on the keyboard and be sure that the scroll lock is off.
Cannot connect to the switch console interface remotely
using Telnet
Action:
The switch IP address is not configured or correct.
From the serial console interface, be sure that the switch IP address is configured and valid on
the network.
Use the correct IP address to establish the Telnet connection with the switch.
The setting allowing access to the switch using the Telnet interface is disabled. From the serial
console interface, be sure that the Telnet interface is enabled.
The management network address/mask (if used) does not contain the IP address of the
management station. From the serial console interface, be sure that the Management Network
Address/Mask contains the IP address of the management station.
Password is not accepted by the switch using the remote
console interface immediately after a reboot
Action:
The switch is still working on network convergence. Wait up to 10 seconds for the password to be
accepted.
Cannot connect to the switch console interface remotely
using SSH
Action: