HP Integrity cx2600 HP Integrity cx2600 Operations and Maintenance Guide - Page 63
Table 4-5 EFI Error and Warning Messages
View all HP Integrity cx2600 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 63 highlights
Table 4-5 EFI Error and Warning Messages (continued) Error Number Message Description/Solution 19 Error writing BMC token on download Communication with the BMC failed. Replace the system board. 20 Non-volatile Memory (NVM) token access error Communication with the BMC failed. Replace the system board. 21 BMC token write error during NVM write Communication with the BMC failed. Replace the through system board. 22 Error reading BMC token on upload to NVM Communication with the BMC failed. Replace the system board. 23 Error reading BMC first boot token Communication with the BMC failed. Replace the system board. 24 Primary field interoperability testing (FIT) failed Reflash firmware. 25 Secondary FIT failed Reflash firmware. 26 Processor abstraction layer (PAL) A warning; Reflash firmware. One copy of PAL is bad 27 PAL A warning; PAL is not compatible with at Update firmware. least 1 CPU 28 Memory errors detected and Page Deallocation Reseat DIMMs; if error persists replace bad Table (PDT) is disabled DIMMs. 30 Memory required reinterleave to get a good Information only, no action required. page 0 31 One or more ranks have chipspare disabled Information only, no action required. 33 One or more memory ranks are mismatched or Check memory installation. Match DIMM part deallocated numbers within each quad. 34 Memory deallocated because of a loading error Check memory installation. DIMMs must be installed with smallest capacity in the first quad, an equal or larger capacity in the second quad, and an equal or larger capacity in the third quad. 35 Memory load order error Check memory installation. DIMMs must be installed with smallest capacity in the first quad, an equal or larger capacity in the second quad, and an equal or largest capacity in the third quad. 36 The PDT is full Clear with pdt clear command in the EFI Shell. 37 At least one CPU has bad fixed core ratio Check processor installation. Verify installation and that identical processors have been installed. 38 All CPUs were slated for compatibility deconfiguration Processor failure. Verify installation and replace processor. Contact the HP Support Center for assistance. 39 Incompatible CPUs detected Check processor installation and match CPU part numbers. CPUs must be identical. 40 CPUs installed with mixed cache sizes Check processor installation. Match CPU part numbers. CPUs must be identical. This always causes a stopboot. 41 CPUs installed with mixed steppings Check processor installation and match CPU part numbers. CPUs must be identical. 42 All CPUs are overclocked Check processor installation and match CPU part numbers. CPUs must be identical. Error Messages 63