HP Integrity cx2600 HP Integrity cx2600 Operations and Maintenance Guide - Page 66

Accessing the Logs with MP Commands, Disk and I/O Path Logging, Text Mode Example

Page 66 highlights

Accessing the Logs with MP Commands The SEL and FPL data can also be accessed from the MP logs using the MP card SL command. The SDM (set display mode) command determines the format of the display: • raw hex mode. • text mode. • keyword mode. Hex Mode Example: 33 0x203E5F914A0200E0 FFFF010944080300 14 0x5680006300E000F0 010000003E5F914A 14 0x5680006300E000F0 0000000000000000 15 0x203E5F914B020110 FFFF027000120300 Text Mode Example: Log Entry 13: 28 Feb 2003 16:41:46 Alert Level 2: Informational Keyword: Type-02 080901 526593 Power supply turned on Logged by: BMC; Sensor: Power Supply - Pwr Spply 1 Ctrl Data1: Device Enabled 0x203E5F914A0200E0 FFFF010944080300 Log Entry 14: 28 Feb 2003 16:41:46 Alert Level 2: Informational Keyword: BOOT_START CPU starting boot Logged by: System Firmware 0 Data: Implementation dependent data field 0x5680006300E000F0 0000000000000000 Log Entry 15: 28 Feb 2003 16:41:47 Alert Level 2: Informational Keyword: Type-02 127002 1208322 Soft Reset Logged by: BMC; Sensor: System Event 0x203E5F914B020110 FFFF027000120300 Keyword Mode Example: 13 BMC 2 0x203E5F914A0200E0 FFFF010944080300 Type-02 080901 526593 28 Feb 2003 16:41:46 14 SFW 0 2 0x5680006300E000F0 0000000000000000 BOOT_START 28 Feb 2003 16:41:46 15 BMC 2 0x203E5F914B020110 FFFF027000120300 Type-02 127002 1208322 28 Feb 2003 16:41:47 Disk and I/O Path Logging Some failures result in I/O path logging. These paths help to indicate the source of the error and can be included in the error message or logged into console or event logs. Table 4-6 and Table 4-7 describe the disk drive and PCI-X slot paths for the server. Table 4-6 Disk and DVD Device Paths Device Slot Slot 0 Slot 1 Slot 2 DVD Path Acpi(HWP0002,100)/Pci(1|0)/Scsi(Pun0,Lun0) Acpi(HWP0002,100)/Pci(1|0))/Scsi(Pun1,Lun0) Acpi(HWP0002,100)/Pci(1|1))/Scsi(Pun2,Lun0) Acpi(HWP0002,0)/Pci(2|0))/Ata(Primary,Master) Rope 1 1 1 0 MHz 66 66 66 33 66 Troubleshooting

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168

Accessing the Logs with MP Commands
The SEL and FPL data can also be accessed from the MP logs using the MP card SL command.
The SDM (set display mode) command determines the format of the display:
raw hex mode.
text mode.
keyword mode.
Hex Mode Example:
33 0x203E5F914A0200E0 FFFF010944080300
14 0x5680006300E000F0 010000003E5F914A
14 0x5680006300E000F0 0000000000000000
15 0x203E5F914B020110 FFFF027000120300
Text Mode Example:
Log Entry 13: 28 Feb 2003 16:41:46
Alert Level 2: Informational
Keyword: Type-02 080901 526593
Power supply turned on
Logged by: BMC; Sensor: Power Supply - Pwr Spply 1 Ctrl
Data1: Device Enabled
0x203E5F914A0200E0 FFFF010944080300
Log Entry 14: 28 Feb 2003 16:41:46
Alert Level 2: Informational
Keyword: BOOT_START
CPU starting boot
Logged by: System Firmware 0
Data: Implementation dependent data field
0x5680006300E000F0 0000000000000000
Log Entry 15: 28 Feb 2003 16:41:47
Alert Level 2: Informational
Keyword: Type-02 127002 1208322
Soft Reset
Logged by: BMC; Sensor: System Event
0x203E5F914B020110 FFFF027000120300
Keyword Mode Example:
13 BMC 2 0x203E5F914A0200E0 FFFF010944080300 Type-02 080901 526593
28 Feb 2003 16:41:46
14 SFW 0 2 0x5680006300E000F0 0000000000000000 BOOT_START
28 Feb 2003 16:41:46
15 BMC 2 0x203E5F914B020110 FFFF027000120300 Type-02 127002 1208322
28 Feb 2003 16:41:47
Disk and I/O Path Logging
Some failures result in I/O path logging. These paths help to indicate the source of the error and
can be included in the error message or logged into console or event logs.
Table 4-6
and
Table 4-7
describe the disk drive and PCI-X slot paths for the server.
Table 4-6 Disk and DVD Device Paths
MHz
Rope
Path
Device Slot
66
1
Acpi(HWP0002,100)/Pci(1|0)/Scsi(Pun0,Lun0)
Slot 0
66
1
Acpi(HWP0002,100)/Pci(1|0))/Scsi(Pun1,Lun0)
Slot 1
66
1
Acpi(HWP0002,100)/Pci(1|1))/Scsi(Pun2,Lun0)
Slot 2
33
0
Acpi(HWP0002,0)/Pci(2|0))/Ata(Primary,Master)
DVD
66
Troubleshooting