HP Integrity rx2620 HP Integrity Servers with Microsoft Windows Server 2003 Re - Page 37

Bypass proxy server for local addresses, Tools > Internet Options, Connections, LAN Settings,

Page 37 highlights

Servers Workaround • HP Array Diagnostic Utility for Windows Server 2003 on Itanium-based systems (CP006361, Hpadu.exe) • HP StorageWorks FC-HBA Configuration Utilities by Emulex for Windows Server 2003 Itanium-based systems (CP006084, HBAnyware.exe) • HP StorageWorks FC-HBA Configuration Utilities by QLogic for Windows Server 2003 Itanium-based systems (CP005831, SANSurferVer.exe) All Integrity Access the component versions manually from the Support Pack, HP Smart Setup CD, or by similar methods. Another solution is to use https://127.0.0.1:2381 instead of https://localhost:2381. SMH fails to open Issue Servers Workaround If Internet Explorer is configured to browse through a proxy server and the Bypass proxy server for local addresses checkbox is not selected, attempting to connect to the local SMH (https://localhost:2381) fails with a Page cannot be displayed error. All Integrity Configure Internet Explorer to bypass the proxy server for local addresses as follows: 1. In Internet Explorer, click Tools > Internet Options. 2. Click the Connections tab. 3. Click LAN Settings. 4. Under Proxy Server, select the Bypass proxy server for local addresses checkbox. Another solution is to use https://127.0.0.1:2381 instead of https://localhost:2381. Program terminates after error message Issue If SMH is frequently installed and then uninstalled, or if the SMH service is frequently stopped and then started again, the following error can be written to the Windows application event log: Faulting application smhstart.exe, version 2.0.0.103, faulting module unknown, version 0.0.0.0, fault address 0x00000000 Servers Workaround All Integrity In most cases, SMH still works normally even after this message appears. However, in rare cases when SMH terminates after this message, you should uninstall SMH, remove the%Windisk%\hp\hpsmh folder, and reinstall SMH. Incorrect number of CPUs displayed in System Report Issue Servers Workaround In the Cell Board Information section of the SMH System Report page, Number of CPUs in Cell refers to logical CPUs. In the Partition Information section, Total Number of Active CPUs also refers to logical CPUs. Physical CPUs are displayed in the Processor Details section. The Processor Details section of the SMH System Report might not reflect the actual number of CPUs recognized and used by the operating system. All Integrity View the correct CPU information in the Operating System section of the Processor Utilization page. Troubleshooting Common Issues 37

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46

HP Array Diagnostic Utility for Windows Server 2003 on Itanium-based
systems (CP006361,
Hpadu.exe
)
HP StorageWorks FC-HBA Configuration Utilities by Emulex for Windows
Server 2003 Itanium-based systems (CP006084,
HBAnyware.exe
)
HP StorageWorks FC-HBA Configuration Utilities by QLogic for Windows
Server 2003 Itanium-based systems (CP005831,
SANSurferVer.exe
)
Servers
All Integrity
Workaround
Access the component versions manually from the Support Pack, HP Smart
Setup CD, or by similar methods.
Another solution is to use
instead of
https://localhost:2381
.
SMH fails to open
Issue
If Internet Explorer is configured to browse through a proxy server and the
Bypass proxy server for local addresses
checkbox is not selected, attempting
to connect to the local SMH (
https://localhost:2381
) fails with a
Page
cannot be displayed
error.
Servers
All Integrity
Workaround
Configure Internet Explorer to bypass the proxy server for local addresses as
follows:
1.
In Internet Explorer, click
Tools > Internet Options
.
2.
Click the
Connections
tab.
3.
Click
LAN Settings
.
4.
Under
Proxy Server
, select the
Bypass proxy server for local addresses
checkbox.
Another solution is to use
instead of
https://localhost:2381
.
Program terminates after error message
Issue
If SMH is frequently installed and then uninstalled, or if the SMH service is
frequently stopped and then started again, the following error can be written
to the Windows application event log:
Faulting application smhstart.exe, version 2.0.0.103,
faulting module unknown, version 0.0.0.0, fault address 0x00000000
Servers
All Integrity
Workaround
In most cases, SMH still works normally even after this message appears.
However, in rare cases when SMH terminates after this message, you should
uninstall SMH, remove the
%Windisk%\hp\hpsmh
folder, and reinstall SMH.
Incorrect number of CPUs displayed in System Report
Issue
In the Cell Board Information section of the SMH System Report page,
Number
of CPUs in Cell
refers to logical CPUs. In the Partition Information section,
Total Number of Active CPUs
also refers to logical CPUs. Physical CPUs
are displayed in the Processor Details section. The Processor Details section of
the SMH System Report might not reflect the actual number of CPUs recognized
and used by the operating system.
Servers
All Integrity
Workaround
View the correct CPU information in the Operating System section of the
Processor Utilization page.
Troubleshooting Common Issues
37