Synopsis Options nPartition Commands Reference fruled fruled The fruled command blinks hardware attention indicators (LEDs) or turns them off. This command can control the cell attention LEDs in all HP nPartition servers, as well as the I/O chassis LEDs on Superdome servers. The fruled command also can start and stop blinking the cabinet number LCDs on HP Superdome compute cabinets and I/O expansion cabinets. fruled [-f|-o] [-B] -c cell [-c...] fruled [-f|-o] [-B] -i IOchassis [-i...] fruled [-f|-o] -b cabinet [-b...] fruled [-f] -C [-l cabinet] [-l...] fruled [-f] -I [-l cabinet] [-l...] • The -h... -g... options must be specified to cause the command to send its management request using IPMI over LAN to a management processor in another server complex (but can also be used as a "loopback access" to the management processor in the local complex). • The -h... -u... set of options must be specified to cause the command to send its management request using WBEM to an nPartition other than the local nPartition (but can also be used as a "loopback access" to the local nPartition). The -g and -u options are mutually exclusive. -f -o -B -c cell -i IOchassis -I IOchassis -b cabinet -C Turn off specified attention LED(s). This is the default. The -f and -o options are mutually exclusive. Start blinking the specified attention LED(s). The -o option is unavailable with -C or -I. Start or stop blinking the cabinet number LCD of the cabinet that contains the cell or I/O chassis. The -B option is only available with -c and -i. link or turn off the specified cell attention LED. cell can be specified either in the local (cabinet/slot) or global (cell_ID) format. Blink or turn off the specified IOchassis attention LED. Turn off all IOchassis LEDs. Start or stop blinking the cabinet number LCD of the specified cabinet. Turn off all cell attention LEDs. Chapter 5 129

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160

nPartition Commands Reference
fruled
Chapter 5
129
fruled
The
fruled
command blinks hardware attention indicators (LEDs) or turns them off.
This command can control the cell attention LEDs in all HP nPartition servers, as well
as the I/O chassis LEDs on Superdome servers. The
fruled
command also can start and
stop blinking the cabinet number LCDs on HP Superdome compute cabinets and I/O
expansion cabinets.
Synopsis
fruled [-f|-o] [-B] -c cell [-c...]
fruled [-f|-o] [-B] -i IOchassis [-i...]
fruled [-f|-o] -b cabinet [-b...]
fruled [-f] -C [-l cabinet] [-l...]
fruled [-f] -I [-l cabinet] [-l...]
The
-h... -g...
options must be specified to cause the command to send its
management request using IPMI over LAN to a management processor in another
server complex (but can also be used as a “loopback access” to the management
processor in the local complex).
The
-h... -u...
set of options must be specified to cause the command to send its
management request using WBEM to an nPartition other than the local nPartition
(but can also be used as a “loopback access” to the local nPartition).
The
-g
and
-u
options are mutually exclusive.
Options
-f
Turn off specified attention LED(s). This is the default.
The
-f
and
-o
options are mutually exclusive.
-o
Start blinking the specified attention LED(s). The
-o
option is
unavailable with
-C
or
-I
.
-B
Start or stop blinking the cabinet number LCD of the cabinet that
contains the cell or I/O chassis.
The
-B
option is only available with
-c
and
-i
.
-c cell
link or turn off the specified
cell
attention LED.
cell
can be specified either in the local (
cabinet/slot
) or global
(
cell_ID
) format.
-i IOchassis
Blink or turn off the specified
IOchassis
attention LED.
-I IOchassis
Turn off all
IOchassis
LEDs.
-b cabinet
Start or stop blinking the cabinet number LCD of the specified
cabinet
.
-C
Turn off all cell attention LEDs.