HP Integrity rx5670 Windows Integrity nPartition Guide - Page 59

List memory configurations

Page 59 highlights

Using Other Tools for Managing nPartitions nPartition-level tasks NOTE You must include the correct remote administration options when issuing par commands (-h and -g for IPMI over LAN connections; -h and -u for WBEM/WMI connections). For a complete explanation of these options, refer to the command description in "nPartition Commands Reference" on page 109. List memory configurations Memory configuration details include summaries of the total memory in a cell or nPartition, the amounts of interleaved memory and cell local memory (where supported) per cell or nPartition, and the number and locations of memory modules (DIMMs) within the cells in a server complex. List memory configurations using the following procedure: Listing memory configurations [par commands] From the command line, issue the parstatus -C command for memory summaries for all cells; use parstatus -V -c# for detailed memory information for the specified cell (-c# where # is the cell number); or use parstatus -V -p# for detailed memory information for the specified nPartition (-p# where # is the nPartition number). Step 1. Login to Windows on the Management Station PC. Step 2. Issue the command to list memory details. • parstatus -C - Cell and memory summaries for all cells in the server complex. • parstatus -V -c# - Detailed memory information for the specified cell (-c# where # is the cell number), including memory module (DIMM) locations and sizes. For HP Integrity servers, this includes details about the interleaved memory in the cell as well as the requested and allocated cell local memory (CLM) amounts. • parstatus -V -p# - Detailed information about the specified nPartition (-p# where # is the nPartition number), including summaries for all assigned cells including their amounts of memory. For HP Integrity servers, the nPartition details include the total good memory size, total interleaved memory, and the total requested and allocated cell local memory (CLM) amounts. NOTE You must include the correct remote administration options when issuing par commands (-h and -g for IPMI over LAN connections; -h and -u for WBEM/WMI connections). For a complete explanation of these options, refer to the command description in "nPartition Commands Reference" on page 109. Chapter 4 59

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160

Using Other Tools for Managing nPartitions
nPartition-level tasks
Chapter 4
59
NOTE
You must include the correct remote administration options when issuing par commands
(
-h
and
-g
for IPMI over LAN connections;
-h
and
-u
for WBEM/WMI connections). For
a complete explanation of these options, refer to the command description in “nPartition
Commands Reference” on page 109.
List memory configurations
Memory configuration details include summaries of the total memory in a cell or
nPartition, the amounts of interleaved memory and cell local memory (where supported)
per cell or nPartition, and the number and locations of memory modules (DIMMs) within
the cells in a server complex.
List memory configurations using the following procedure:
Listing memory configurations [par commands]
From the command line, issue the
parstatus -C
command for memory summaries for
all cells; use
parstatus -V -c#
for detailed memory information for the specified cell
(
-c#
where
#
is the cell number); or use
parstatus -V -p#
for detailed memory
information for the specified nPartition (
-p#
where
#
is the nPartition number).
Step 1.
Login to Windows on the Management Station PC.
Step 2.
Issue the command to list memory details.
parstatus -C
— Cell and memory summaries for all cells in the server complex.
parstatus -V -c#
— Detailed memory information for the specified cell (
-c#
where
#
is the cell number), including memory module (DIMM) locations and sizes. For HP
Integrity servers, this includes details about the interleaved memory in the cell as
well as the requested and allocated cell local memory (CLM) amounts.
parstatus -V -p#
— Detailed information about the specified nPartition (
-p#
where
#
is the nPartition number), including summaries for all assigned cells including
their amounts of memory. For HP Integrity servers, the nPartition details include the
total good memory size, total interleaved memory, and the total requested and
allocated cell local memory (CLM) amounts.
NOTE
You must include the correct remote administration options when issuing par commands
(
-h
and
-g
for IPMI over LAN connections;
-h
and
-u
for WBEM/WMI connections). For
a complete explanation of these options, refer to the command description in “nPartition
Commands Reference” on page 109.