HP Integrity rx6600 HP Insight Manager WBEM Provider Events Reference - Page 22
OS INIT address not registered. Probable Cause: The OS has not registered an OS_INIT
View all HP Integrity rx6600 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 22 highlights
Event ID Event Severity 5252 Warning 5253 Warning 5255 Warning 5256 Warning 5257 Warning 5260 Warning 5263 Warning 5264 Warning 5266 Error 5268 Warning 5270 Warning 5278 Warning 5279 Error Event Description The DIMM Loading Order check was bypassed. Probable Cause: Control bit to skip DIMM loading order check is set. Recommended Action: Clear NVM. Recommended action: Update PDC. Recommended action: Contact HP support to troubleshoot the problem. WBEM EventID: 334. WBEM ProviderName: FPL_IndicationProvider. Looping on destructive memory tests. Probable Cause: Control bit to loop on destructive memory test is set. Recommended Action: Clear NVM. Recommended action: Update PDC. Recommended action: Contact HP support to troubleshoot the problem. WBEM EventID: 335. WBEM ProviderName: FPL_IndicationProvider. DIMM Set Check has been skipped. Probable Cause: Control bit to skip DIMM set check is set. Recommended Action: Clear NVM. Recommended action: Update PDC. Recommended action: Contact HP support to troubleshoot the problem. WBEM EventID: 336. WBEM ProviderName: FPL_IndicationProvider. Serial Presence Detect (SPD) has been skipped. Probable Cause: Control bit to skip DIMM SPD check is set. Recommended Action: Clear NVM. Recommended action: Update PDC. Recommended action: Contact HP support to troubleshoot the problem. WBEM EventID: 337. WBEM ProviderName: FPL_IndicationProvider. An Alternate Memory Config has been loaded into the system. Probable Cause: Control bit to use an alternate memory config are set. Recommended Action: Clear NVM Update SFW Contact HP support to troubleshoot the problem. WBEM EventID: 338. WBEM ProviderName: FPL_IndicationProvider. OS INIT address not registered. Probable Cause: The OS has not registered an OS_INIT vector. Recommended Action: No action is required. The OS has failed to register the vector or has chosen not to. WBEM EventID: 340. WBEM ProviderName: FPL_IndicationProvider. OS MCA address not registered. Probable Cause: The OS has not registered an OS_MCA vector. Recommended Action: None, the OS has failed to register the vector or has chosen not to. WBEM EventID: 341. WBEM ProviderName: FPL_IndicationProvider. OS MCA did not correct the Machine Check. Probable Cause: Uncorrected Machine Check. Recommended Action: Analyze cause of Machine Check using diagnostic and EFI tools. WBEM EventID: 342. WBEM ProviderName: FPL_IndicationProvider. Found bad miscellaneous register. Probable Cause: A PDH register has failed. Recommended Action: Reboot if necessary, if problem persists contact your HP representative for support. WBEM EventID: 343. WBEM ProviderName: FPL_IndicationProvider. SAL_CHECK failed for an unknown reason. Probable Cause: The handler for SAL_CHECK has failed for an unknown reason. Recommended Action: Reboot if necessary, if problem persists contact your HP representative for support. WBEM EventID: 344. WBEM ProviderName: FPL_IndicationProvider. SAL_INIT failed for an unknown reason. Probable Cause: The handler for SAL_INIT has failed for an unknown reason. Recommended Action: Reboot if necessary, if problem persists contact your HP representative for support. WBEM EventID: 345. WBEM ProviderName: FPL_IndicationProvider. Unspecified memory interleave error. Probable Cause: FW encountered a fatal interleaving error. Recommended Action: Update SFW. Recommended action: Contact HP support to troubleshoot the problem. WBEM EventID: 346. WBEM ProviderName: FPL_IndicationProvider. Unexpected return to SAL_CHECK. Probable Cause: Unexpected return to SAL_CHECK. Recommended Action: Reboot if necessary, if problem persists contact your HP representative for support. WBEM EventID: 347. WBEM ProviderName: FPL_IndicationProvider. 22 WBEM Provider Event Tables