HP Integrity rx6600 HP Insight Manager WBEM Provider Events Reference - Page 7
WBEM Provider Event Tables, Introduction, Platform Events - service guide
View all HP Integrity rx6600 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 7 highlights
1 WBEM Provider Event Tables Introduction This reference guide describes the Windows System Log Event ID number, severity, and description of events generated by HP Integrity WBEM provider software. The WBEM providers are a group of services that run continuously in the background on HP Integrity servers and report the status of system components. Each WBEM provider has its own unique table in this document. Each row in the Platform Events table includes the following information about the event: • ID number in the Windows System Log (the table is sorted on this field, in ascending order) • Severity (Warning or Error) • Description, which includes the following information: - a short description of the event - probable cause of the event - the recommended course of action - the WBEM EventID that generated the event - the WBEM provider name Each row in the remaining WBEM provider event tables includes the following information about the event: • ID number in the Windows System Log (the table is sorted on this field, in ascending order) • Severity (Informational, Warning, or Error) • Description Platform Events Table #1 - Event ID numbers 0 through 8,999 Event ID Event Severity 752 Warning 753 Error Event Description Temperature sensor crossed lower non-critical threshold. Probable Cause: The temperature inside the server has gone outside the factory specified range for normal operation. You should quit applications and power down the server to protect its hardware from damage. This event may indicate one of the following conditions: A failed fan, blocked air vents or poor ventilation around the server, open server chassis cover, or missing drive slot covers, high temperature in the room where the server resides, an unusually hot hardware component located near one of the server's temperature sensors. Recommended Action: You should quit applications and shutdown the system. Find cause of temperature anomaly and fix it. WBEM EventID: 100. WBEM ProviderName: SEL02_IndicationProvider. A temperature inside the server went far outside the factory specified range. Probable Cause: The temperature inside the server has gone far outside the factory specified range for normal operation. To avoid permanent damage to your server hardware, go and turn off the server immediately. This event may indicate one of the following conditions: a failed fan blocked air vents or poor ventilation around the server open server chassis cover, or missing drive slot covers high temperature in the room where the server resides an unusually hot hardware component located near one of the server's temperature sensors. Recommended action: Shutdown the system immediately. Find cause of temperature anomaly and fix it. WBEM EventID: 101. WBEM ProviderName: SEL02_IndicationProvider. Introduction 7