HP Integrity rx6600 HP Insight Manager WBEM Provider Events Reference - Page 36

versions of EFI and SAL, Internal EFI error. Recommended Action: Reboot. If problem

Page 36 highlights

Event ID Event Severity 5766 Error 5767 Error 5768 Warning 5769 Warning 5770 Warning 5771 Warning 5772 Error 5774 Error 5776 Warning 5777 Warning 5778 Warning 5779 Warning 5784 Error 5785 Error Event Description There was an error while initializing the Concorde-Xbc interface. Probable Cause: An XBC is indicating a port failure Recommended Action: Validate all of the cells connectivity to the PD Check the XBC chips seating reset the system replace either cells/system backplane. WBEM EventID: 507. WBEM ProviderName: FPL_IndicationProvider. The CC - XBC link failed to initialize. Probable Cause: An XBC is indicating a port failure Recommended Action: Validate all of the cells connectivity to the PDCheck the XBC chips seating reset the system replace either cells/system backplane. WBEM EventID: 508. WBEM ProviderName: FPL_IndicationProvider. Unable to determine system mode because EFI/SAL interface not initialized. Probable Cause: Internal EFI error. Recommended Action: Upgrade system firmware. If problem persists, contact HP support to troubleshoot the problem. WBEM EventID: 509. WBEM ProviderName: FPL_IndicationProvider. BMC returned an invalid system mode. Probable Cause: Mismatch between BMC and EFI firmware. Recommended Action: Upgrade system firmware or BMC firmware as necessary. If problem persists, contact HP support to troubleshoot the problem. WBEM EventID: 510. WBEM ProviderName: FPL_IndicationProvider. EFI unable to specify system mode because EFI/SAL interface not initialized. Probable Cause: Internal EFI error. Recommended Action: Upgrade system firmware. If problem persists, contact HP support to troubleshoot the problem. WBEM EventID: 511. WBEM ProviderName: FPL_IndicationProvider. Unable to enter normal system mode because EFI/SAL interface not initialized. Probable Cause: Internal EFI error. Recommended Action: Upgrade system firmware. If problem persists, contact HP support to troubleshoot the problem. WBEM EventID: 512. WBEM ProviderName: FPL_IndicationProvider. Unable to initialize part of the SAL/EFI interface. Probable Cause: Incompatible versions of EFI and SAL, Internal EFI error. Recommended Action: Reboot. If problem persists contact your HP representative for support. WBEM EventID: 513. WBEM ProviderName: FPL_IndicationProvider. An expected tree node was not found. Probable Cause: This is a bug. Contact engineering. WBEM EventID: 515. WBEM ProviderName: FPL_IndicationProvider. EFI unable to modify system state to 'running'. Probable Cause: BMC non functional. Recommended Action: Contact your HP representative to check the BMC. WBEM EventID: 516. WBEM ProviderName: FPL_IndicationProvider. /options settings for CPUBusConfigValue aren't compatible with PAL. Probable Cause: Update the /options value to comply with the desired features and what is supported. WBEM EventID: 2433. WBEM ProviderName: FPL_IndicationProvider. The Get Processor Bus Dependent Configuration Features PAL call failed. Probable Cause: Contact engineering. There is a PAL compatibility problem. WBEM EventID: 518. WBEM ProviderName: FPL_IndicationProvider. memory DIMM pair mismatch. Probable Cause: The user installed a mismatched pair of DIMMs in the same rank (i.e. the DIMMs are different size or DRAM width). Recommended Action: Install memory ranks in pairs of DIMMs that are the same size and DRAM width. WBEM EventID: 519. WBEM ProviderName: FPL_IndicationProvider. EFI unable to initialize internal library. Probable Cause: Internal EFI error. Recommended Action: Reboot. If problem persists contact your HP representative for support. WBEM EventID: 520. WBEM ProviderName: FPL_IndicationProvider. EFI unable to initialize security system. Probable Cause: BMC not responding properly. Recommended Action: Reset BMC. Contact your HP representative if problem persists. WBEM EventID: 521. WBEM ProviderName: FPL_IndicationProvider. 36 WBEM Provider Event Tables

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112

Event Description
Event
Severity
Event ID
There was an error while initializing the Concorde-Xbc interface. Probable Cause:
An XBC is indicating a port failure Recommended Action: Validate all of the cells
connectivity to the PD Check the XBC chips seating reset the system replace either
cells/system backplane. WBEM EventID: 507. WBEM ProviderName:
FPL_IndicationProvider.
Error
5766
The CC - XBC link failed to initialize. Probable Cause: An XBC is indicating a port
failure Recommended Action: Validate all of the cells connectivity to the PDCheck
the XBC chips seating reset the system replace either cells/system backplane. WBEM
EventID: 508. WBEM ProviderName: FPL_IndicationProvider.
Error
5767
Unable to determine system mode because EFI/SAL interface not initialized. Probable
Cause: Internal EFI error. Recommended Action: Upgrade system firmware. If
problem persists, contact HP support to troubleshoot the problem. WBEM EventID:
509. WBEM ProviderName: FPL_IndicationProvider.
Warning
5768
BMC returned an invalid system mode. Probable Cause: Mismatch between BMC
and EFI firmware. Recommended Action: Upgrade system firmware or BMC firmware
as necessary. If problem persists, contact HP support to troubleshoot the problem.
WBEM EventID: 510. WBEM ProviderName: FPL_IndicationProvider.
Warning
5769
EFI unable to specify system mode because EFI/SAL interface not initialized. Probable
Cause: Internal EFI error. Recommended Action: Upgrade system firmware. If
problem persists, contact HP support to troubleshoot the problem. WBEM EventID:
511. WBEM ProviderName: FPL_IndicationProvider.
Warning
5770
Unable to enter normal system mode because EFI/SAL interface not initialized.
Probable Cause: Internal EFI error. Recommended Action: Upgrade system firmware.
If problem persists, contact HP support to troubleshoot the problem. WBEM EventID:
512. WBEM ProviderName: FPL_IndicationProvider.
Warning
5771
Unable to initialize part of the SAL/EFI interface. Probable Cause: Incompatible
versions of EFI and SAL, Internal EFI error. Recommended Action: Reboot. If problem
persists contact your HP representative for support. WBEM EventID: 513. WBEM
ProviderName: FPL_IndicationProvider.
Error
5772
An expected tree node was not found. Probable Cause: This is a bug. Contact
engineering. WBEM EventID: 515. WBEM ProviderName: FPL_IndicationProvider.
Error
5774
EFI unable to modify system state to 'running'. Probable Cause: BMC non functional.
Recommended Action: Contact your HP representative to check the BMC. WBEM
EventID: 516. WBEM ProviderName: FPL_IndicationProvider.
Warning
5776
/options settings for CPUBusConfigValue aren't compatible with PAL. Probable
Cause: Update the /options value to comply with the desired features and what is
supported. WBEM EventID: 2433. WBEM ProviderName: FPL_IndicationProvider.
Warning
5777
The Get Processor Bus Dependent Configuration Features PAL call failed. Probable
Cause: Contact engineering. There is a PAL compatibility problem. WBEM EventID:
518. WBEM ProviderName: FPL_IndicationProvider.
Warning
5778
memory DIMM pair mismatch. Probable Cause: The user installed a mismatched
pair of DIMMs in the same rank (i.e. the DIMMs are different size or DRAM width).
Recommended Action: Install memory ranks in pairs of DIMMs that are the same
size and DRAM width. WBEM EventID: 519. WBEM ProviderName:
FPL_IndicationProvider.
Warning
5779
EFI unable to initialize internal library. Probable Cause: Internal EFI error.
Recommended Action: Reboot. If problem persists contact your HP representative
for support. WBEM EventID: 520. WBEM ProviderName: FPL_IndicationProvider.
Error
5784
EFI unable to initialize security system. Probable Cause: BMC not responding
properly. Recommended Action: Reset BMC. Contact your HP representative if
problem persists. WBEM EventID: 521. WBEM ProviderName:
FPL_IndicationProvider.
Error
5785
36
WBEM Provider Event Tables