HP Integrity rx6600 HP Insight Manager WBEM Provider Events Reference - Page 94
Recommended Action: Update SFW. Contact your HP representative for support.
View all HP Integrity rx6600 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 94 highlights
Event ID Event Severity 11788 Warning 11789 Warning 11797 Warning 11807 Warning 11840 Warning 11850 Error 11851 Warning 11863 Warning 11870 Warning 11885 Warning Event Description SFW failed to allocate enough NVM to store all required data. Probable Cause: Not enough space allocated to store all required data in NVM. Recommended Action: Upgrade FW Contact HP support. WBEM EventID: 6857. WBEM ProviderName: FPL_IndicationProvider. SFW failed to allocate enough SCR RAM to store all required data. Probable Cause: SFW component does not allocate enough space in the SCR RAM for store it data. Recommended Action: Update SFW. Contact your HP representative for support. WBEM EventID: 6858. WBEM ProviderName: FPL_IndicationProvider. SetupIntialCohTables() returned an error in ArfPhase3. Data field: cell set [63:32], return value [31:0]. Probable Cause: An error occurred while routing the fabric. Recommended Action: Collect IPMI event logs, and contact your HP support representative to inspect the fabric and system firmware. WBEM EventID: 5157. WBEM ProviderName: FPL_IndicationProvider. Error writing the error masks for ALREC and ALTRAN. Data field: cell ID [63:56], port num [55:44], XBC ID [43:32]. Probable Cause: An error occurred while routing the fabric. Recommended Action: Collect IPMI event logs, and contact your HP support representative to inspect the fabric and system firmware. WBEM EventID: 5161. WBEM ProviderName: FPL_IndicationProvider. Firmware had an unexpected internal error from the vertex module.. Data field: vType1 [63:56] | vPort1 [55:48] | vId1 [47:32] | vType2 [31:24] | vPort2 [23:16] | vId2 [15:0]. Probable Cause: An error occurred while routing the fabric, possible data corruption or firmware error. Recommended Action: Collect IPMI event logs, and contact your HP support representative to inspect the fabric and system firmware. WBEM EventID: 5162. WBEM ProviderName: FPL_IndicationProvider. The OS being booted is not supported in a partition containing a mix of processor stepping revisions. Probable Cause: The OS being booted is not supported in a partition containing a mix of processor stepping revisions. Recommended Action: Failed processors should be replaced with like processors. Reconfigure the hardware to avoid configurations with mixed steppings. WBEM EventID: 5163. WBEM ProviderName: FPL_IndicationProvider. Firmware had an unexpected error while setting up links. Data field: vType1 [63:56] | vPort1 [55:48] | vId1 [47:32] | vType2 [31:24] | vPort2 [23:16] | vId2 [15:0]. Probable Cause: An error occurred while routing the fabric, possible data corruption or firmware error. Recommended Action: Collect IPMI event logs, and contact your HP support representative to inspect the fabric and system firmware. WBEM EventID: 5164. WBEM ProviderName: FPL_IndicationProvider. Firmware was unable to write the Skyline global LINK_SEL_COHx CSR. Data field: cell num [63:56] | link sel coh CSR (0 or 1) [0:0]. Probable Cause: An error occurred while routing the fabric. Recommended Action: Collect IPMI event logs, and contact your HP support representative to inspect the fabric and system firmware. WBEM EventID: 5165. WBEM ProviderName: FPL_IndicationProvider. The requested OS does not support booting with mixed CPU revisions. Probable Cause: Mixed CPU revisions exist in a mixed-cpu stepping configuration. Recommended Action: Replace cells to match cpu stepping revisions or deconfigure the unmatched processors. WBEM EventID: 5166. WBEM ProviderName: FPL_IndicationProvider. System firmware experienced an error while updating the link sel value. Data field indicates return status. Probable Cause: Error updating the global link select fabric value Recommended Action: Contact your HP Support Representative to investigate the fabric subsystem. WBEM EventID: 5167. WBEM ProviderName: FPL_IndicationProvider. 94 WBEM Provider Event Tables