HP Integrity rx6600 HP Insight Manager WBEM Provider Events Reference - Page 52

Attempt to update the PD PDT with OLA Cell failed. Probable Cause: Unable to add

Page 52 highlights

Event ID Event Severity 8263 Warning 8264 Warning 8265 Warning 8267 Warning 8269 Warning 8271 Error 8643 Warning 8645 Error 8646 Error 8647 Warning 8648 Error 8652 Error Event Description Partition attempted to OLA a cell that was not fully ready for the operation. Probable Cause: OLA cell hung during its part of the OLA process. Consult chassis codes from the OLA cell to determine what happened. A secondary problem here is that the root cell attempted to OLA a cell that could not have sent the Ready to OLA command (since it hung). This would indicate a failure on the OS side to correctly handle OLA-associated interrupts. Recommended Action: Collect IPMI events and contact HP Customer Support for assistance. WBEM EventID: 6950. WBEM ProviderName: FPL_IndicationProvider. Partition attempted to OLA a cell still waiting at BIB. Probable Cause: Interrupt problem. Root cell should not attempt to OLA a cell until that cell send the Ready to OLA message, which a cell at BIB cannot have done. Recommended Action: Attempt the OLA operation again. If failure continues, gather IPMI event logs and contact HP Customer Support for assistance. WBEM EventID: 6951. WBEM ProviderName: FPL_IndicationProvider. Partition attempted to OLA a cell in an unexpected Cell state. Probable Cause: OLA cell has reached unknown state after sending Ready to OLA command, or OLA was attempted on cell that was not ready to OLA. Recommended Action: Attempt the OLA operation again, or collect IPMI event logs and contact HP Customer Support for assistance. WBEM EventID: 6952. WBEM ProviderName: FPL_IndicationProvider. OLA cell was unable to reach some cell(s) in the alive set. Probable Cause: Bad fabric link between OLA cell and cells already in the partition. Recommended Action: Fabric links between cells may have failed. Contact HP Customer Support for assistance. WBEM EventID: 6953. WBEM ProviderName: FPL_IndicationProvider. CPUs of different maximum core frequencies are installed. Probable Cause: CPU's of mixed maximum core frequencies are installed. Recommended Action: Install CPU's with the same speed and cache size. WBEM EventID: 753. WBEM ProviderName: FPL_IndicationProvider. The RVL CC-Togo link initialization workaround (PS221) failed. Probable Cause: Hardware link initialization failed. Recommended Action: Contact HP support. Reset cell. WBEM EventID: 2466. WBEM ProviderName: FPL_IndicationProvider. PDC failed clearing the OLA steering bit in the Dillon microstatus reg. Probable Cause: Probably something wrong with the cell hardware. Recommended Action: Try OLAing a different cell. Contact HP Support personnel to troubleshoot the problem. WBEM EventID: 1761. WBEM ProviderName: FPL_IndicationProvider. The attempt to update the PD Addr Map to include OLA cell failed. Probable Cause: System FW was unable to add the OLA cell's memory to the PD address map. Error writing to PDH space. Likely cell board error Recommended Action: Collect IPMI event logs and contact HP Support. WBEM EventID: 6958. WBEM ProviderName: FPL_IndicationProvider. Attempt to update the PD PDT with OLA Cell failed. Probable Cause: Unable to add OLA cell's PDT to the partition PDT. Error accessing PDH space. Check fabric connection between OLA cell and core cell. Recommended Action: Gather IPMI event logs and contact HP Support. WBEM EventID: 6959. WBEM ProviderName: FPL_IndicationProvider. Attempt to update the cell map to include the OLA Cell failed. Probable Cause: Unable to write registers on the CC. Check cell board and system fabric. Recommended Action: Collect IPMI events and contact HP Support. WBEM EventID: 6960. WBEM ProviderName: FPL_IndicationProvider. Fabric Discovery could not initialize the local cell's XBC link. Probable Cause: CC to XBC link init failure. Recommended Action: check CC, XBC, reset cell, reset backplane. WBEM EventID: 756. WBEM ProviderName: FPL_IndicationProvider. Internal firmware programming error. Probable Cause: Report the IP to the firmware team. Reset the system. This cannot be worked around in the field. WBEM EventID: 760. WBEM ProviderName: FPL_IndicationProvider. 52 WBEM Provider Event Tables

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112

Event Description
Event
Severity
Event ID
Partition attempted to OLA a cell that was not fully ready for the operation. Probable
Cause: OLA cell hung during its part of the OLA process. Consult chassis codes from
the OLA cell to determine what happened. A secondary problem here is that the root
cell attempted to OLA a cell that could not have sent the Ready to OLA command
(since it hung). This would indicate a failure on the OS side to correctly handle
OLA-associated interrupts. Recommended Action: Collect IPMI events and contact
HP Customer Support for assistance. WBEM EventID: 6950. WBEM ProviderName:
FPL_IndicationProvider.
Warning
8263
Partition attempted to OLA a cell still waiting at BIB. Probable Cause: Interrupt
problem. Root cell should not attempt to OLA a cell until that cell send the Ready to
OLA message, which a cell at BIB cannot have done. Recommended Action: Attempt
the OLA operation again. If failure continues, gather IPMI event logs and contact HP
Customer Support for assistance. WBEM EventID: 6951. WBEM ProviderName:
FPL_IndicationProvider.
Warning
8264
Partition attempted to OLA a cell in an unexpected Cell state. Probable Cause: OLA
cell has reached unknown state after sending Ready to OLA command, or OLA was
attempted on cell that was not ready to OLA. Recommended Action: Attempt the
OLA operation again, or collect IPMI event logs and contact HP Customer Support
for assistance. WBEM EventID: 6952. WBEM ProviderName: FPL_IndicationProvider.
Warning
8265
OLA cell was unable to reach some cell(s) in the alive set. Probable Cause: Bad fabric
link between OLA cell and cells already in the partition. Recommended Action: Fabric
links between cells may have failed. Contact HP Customer Support for assistance.
WBEM EventID: 6953. WBEM ProviderName: FPL_IndicationProvider.
Warning
8267
CPUs of different maximum core frequencies are installed. Probable Cause: CPU's
of mixed maximum core frequencies are installed. Recommended Action: Install
CPU's with the same speed and cache size. WBEM EventID: 753. WBEM
ProviderName: FPL_IndicationProvider.
Warning
8269
The RVL CC-Togo link initialization workaround (PS221) failed. Probable Cause:
Hardware link initialization failed. Recommended Action: Contact HP support. Reset
cell. WBEM EventID: 2466. WBEM ProviderName: FPL_IndicationProvider.
Error
8271
PDC failed clearing the OLA steering bit in the Dillon microstatus reg. Probable
Cause: Probably something wrong with the cell hardware. Recommended Action:
Try OLAing a different cell. Contact HP Support personnel to troubleshoot the
problem. WBEM EventID: 1761. WBEM ProviderName: FPL_IndicationProvider.
Warning
8643
The attempt to update the PD Addr Map to include OLA cell failed. Probable Cause:
System FW was unable to add the OLA cell's memory to the PD address map. Error
writing to PDH space. Likely cell board error Recommended Action: Collect IPMI
event logs and contact HP Support. WBEM EventID: 6958. WBEM ProviderName:
FPL_IndicationProvider.
Error
8645
Attempt to update the PD PDT with OLA Cell failed. Probable Cause: Unable to add
OLA cell's PDT to the partition PDT. Error accessing PDH space. Check fabric
connection between OLA cell and core cell. Recommended Action: Gather IPMI event
logs and contact HP Support. WBEM EventID: 6959. WBEM ProviderName:
FPL_IndicationProvider.
Error
8646
Attempt to update the cell map to include the OLA Cell failed. Probable Cause:
Unable to write registers on the CC. Check cell board and system fabric.
Recommended Action: Collect IPMI events and contact HP Support. WBEM EventID:
6960. WBEM ProviderName: FPL_IndicationProvider.
Warning
8647
Fabric Discovery could not initialize the local cell's XBC link. Probable Cause: CC to
XBC link init failure. Recommended Action: check CC, XBC, reset cell, reset backplane.
WBEM EventID: 756. WBEM ProviderName: FPL_IndicationProvider.
Error
8648
Internal firmware programming error. Probable Cause: Report the IP to the firmware
team. Reset the system. This cannot be worked around in the field. WBEM EventID:
760. WBEM ProviderName: FPL_IndicationProvider.
Error
8652
52
WBEM Provider Event Tables