is the processor IFA. Probable Cause: Probable bug in System Firmware, EFI driver, EFI
View all HP Integrity rx6600 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 99 highlights
Event ID Event Severity 12135 Warning 12143 Warning 12144 Warning 12149 Error 12150 Error 12153 Warning 12155 Error 12156 Warning 12157 Warning 12159 Warning 12160 Warning Event Description Duplicate DIMM serial numbers have been detected. Data field gives physical location of DIMM. Check for other events specifying other DIMMs with same serial number. Probable Cause: Multiple DIMMs have the same serial number. Recommended Action: Replace DIMMs with duplicate serial numbers. Ensure new DIMMs have unique serial numbers. WBEM EventID: 6564. WBEM ProviderName: FPL_IndicationProvider. The MP has lost lan communication with the UPS. WBEM EventID: 6833. WBEM ProviderName: FPL_IndicationProvider. The MP has re-gained lan communication with the UPS. WBEM EventID: 6834. WBEM ProviderName: FPL_IndicationProvider. An unrecoverable processor interrupt occurred while in IPF firmware. The data value is the processor IFA. Probable Cause: Probable bug in System Firmware, EFI driver, EFI app or OS loader (prior to OS launch). The event data field contains the IVT offset applicable to the interrupt. See table 5-7 (Interruption Vector Table) in the Intel ASDM Volume 2. Recommended Action: Provide console log containing register dump to HP Customer Engineer. WBEM EventID: 6569. WBEM ProviderName: FPL_IndicationProvider. An unrecoverable processor interrupt occurred while in IPF firmware. The event data is the processor ISR. Probable Cause: Probable bug in System Firmware, EFI driver, EFI app or OS loader (prior to OS launch). The event data field contains the IVT offset applicable to the interrupt. See table 5-7 (Interruption Vector Table) in the Intel ASDM Volume 2. Recommended Action: Provide console log containing register dump to HP Customer Engineer. WBEM EventID: 6570. WBEM ProviderName: FPL_IndicationProvider. Double chip sparing has been invoked. Probable Cause: System firmware has detected and corrected memory errors. Double chip sparing has been invoked to help mitigate this condition. Recommended Action: On the next reboot, system firmware will test the specified memory components, and may take them offline if the errors persist. contact your HP support representative to check the specified memory components at your next scheduled downtime. WBEM EventID: 6572. WBEM ProviderName: FPL_IndicationProvider. External clock cable has been removed from the CPU cabinet. The data field contains the physical location of the cabinet. Probable Cause: External clock cable has been removed from the CPU cabinet. Recommended Action: Check external clock cable. WBEM EventID: 6575. WBEM ProviderName: FPL_IndicationProvider. System Fabric encountered a link error after opening up the fabric link. Probable Cause: Fabric link errors were encountered Recommended Action: Collect IPMI event logs. Contact your HP Support Representative to check the health of the system fabric. WBEM EventID: 6576. WBEM ProviderName: FPL_IndicationProvider. Fatal errors are present on a cell's link to the fabric. Data Field: (crossbar port 44) | (crossbar 32) | 1. Probable Cause: Fatal errors are present on the cell to crossbar links Recommended Action: Collect IPMI Event logs. Contact your HP Support Representative to check the fabric subsystem health. WBEM EventID: 6577. WBEM ProviderName: FPL_IndicationProvider. System firmware encountered fabric problems. Data Field: (crossbar port 44) | (crossbar 32). Probable Cause: Errors occurred while collecting error data from a fabric link Recommended Action: Collect IPMI Event logs. Contact your HP Support Representative to check the fabric subsystem health. WBEM EventID: 6579. WBEM ProviderName: FPL_IndicationProvider. Fatal errors are present on a cell's link to the fabric. Data Field: (crossbar port 44) | (crossbar 32). Probable Cause: Fatal errors are present on a cell to crossbar link Recommended Action: Collect IPMI Event logs. Contact your HP Support Representative to check the fabric subsystem health. WBEM EventID: 6580. WBEM ProviderName: FPL_IndicationProvider. Platform Events 99