HP Integrity rx6600 HP Insight Manager WBEM Provider Events Reference - Page 26
The Freelist used for NVM block allocation is corrupt. Probable Cause: Band NVRAM
View all HP Integrity rx6600 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 26 highlights
Event ID Event Severity 5474 Warning 5478 Error 5479 Error 5483 Error 5485 Error 5490 Error 5491 Error 5492 Error 5493 Error 5494 Warning 5496 Error 5498 Error 5499 Warning 5500 Warning 5501 Warning 5502 Error 5503 Error 5505 Error Event Description CellInfoList is not NULL. Probable Cause: Reset. WBEM EventID: 396. WBEM ProviderName: FPL_IndicationProvider. Error in constructing the Memory Descriptor. Probable Cause: Reset. WBEM EventID: 397. WBEM ProviderName: FPL_IndicationProvider. Unable to update the local memory layout. Probable Cause: Reset. WBEM EventID: 398. WBEM ProviderName: FPL_IndicationProvider. A required address was not found within a mapped address. Probable Cause: Reset. WBEM EventID: 399. WBEM ProviderName: FPL_IndicationProvider. Failure to install a Partition level PDT. Probable Cause: Reset. WBEM EventID: 400. WBEM ProviderName: FPL_IndicationProvider. A critical resource could not be found or is unusable. Probable Cause: Determine the failing component or hardware from the data field as described and replace. WBEM EventID: 401. WBEM ProviderName: FPL_IndicationProvider. Internal firmware programming error. Probable Cause: Report the IP to the firmware team. Reset the system. This cannot be worked around in the field. WBEM EventID: 402. WBEM ProviderName: FPL_IndicationProvider. NVRam test failed with a data compare error. Probable Cause: Bad NVRam, replace the bad chip. WBEM EventID: 2426. WBEM ProviderName: FPL_IndicationProvider. An NVRam CRC Error was detected. Probable Cause: Firmware/software error Recommended Action: Check for new version of firmware/OS Contact HP Support. WBEM EventID: 2427. WBEM ProviderName: FPL_IndicationProvider. The Error Response Mode has been determined. Probable Cause: Decode the hex vales to ASCII to determine the mode. Other errors will determine action. WBEM EventID: 4523. WBEM ProviderName: FPL_IndicationProvider. A semaphore could not be obtained. Probable Cause: Recommended Action: Reset system to clear the semaphore Try reinitializing NVRAM. If problem persists, contact engineering. WBEM EventID: 405. WBEM ProviderName: FPL_IndicationProvider. The BLOCK requested in NVRAM has the wrong revision. Probable Cause: Clear NVRAM and reset. WBEM EventID: 2428. WBEM ProviderName: FPL_IndicationProvider. The requested NVRAM block was not found. Probable Cause: No Action Required. Firmware can allocated space for the block. WBEM EventID: 407. WBEM ProviderName: FPL_IndicationProvider. The requested NVRAM block is locked. Probable Cause: Retry the operation. WBEM EventID: 408. WBEM ProviderName: FPL_IndicationProvider. Firmware tried to unlock a NVRAM block that was already unlocked. Probable Cause: No action required. WBEM EventID: 409. WBEM ProviderName: FPL_IndicationProvider. The Header in NVRAM was not found. Probable Cause: NVRAM cannot be used. It must be initialized first. Firmware will attempt the initialization. WBEM EventID: 410. WBEM ProviderName: FPL_IndicationProvider. The Freelist used for NVM block allocation is corrupt. Probable Cause: Band NVRAM/ reinitialize. WBEM EventID: 411. WBEM ProviderName: FPL_IndicationProvider. Firmware is preparing to reset for reconfiguration. Probable Cause: This can be caused by many conditions including a bad complex profile, a bad hardware configuration, a cell arriving late to the rendezvous point. A cell not being able to rendezvous. Reconfiguration from partition manager is recommended. WBEM EventID: 412. WBEM ProviderName: FPL_IndicationProvider. 26 WBEM Provider Event Tables