HP LH4r HP Netserver LXr 8500 Rack Cabling Guide - Page 24

The 200/240 VAC, wide-range Power Distribution Unit PDU can be mounted

Page 24 highlights

Chapter 2 Rack Cabling References The 200/240 VAC, wide-range Power Distribution Unit (PDU) can be mounted in several configurations with the LXr 8500. One of these configurations is shown in Figure 2-2. Others are listed and illustrated throughout Chapter 3. How to Position the PDU Count the receptacles needed for each unit in the rack, notice where the PDUs can be most conveniently located, and decide whether to orient the PDU vertically or horizontally. Horizontal Mounting of Two PDUs in a Fully Utilized Rack Cable Guides Mounted on the Column Across from the Door Hinges Examples of Data Cable Routes from Server to Connectors on Other Components 200-240 VAC WideRange 10-Amp, 19-Inch Power Distribution Unit, Installed Horizontally Behind the Monitor (Power Cord Connections to Equipment Are Not Illustrated Here) Data Cables Routed through Cable Management Arm 200-240 VAC WideRange 16-Amp PDU Mounted Horizontally Behind the Uninterruptible Power Supply Figure 2-2. Mounting a Pair of PDUs Horizontally (Rear View) 20

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59

Chapter 2
Rack Cabling References
20
The 200/240 VAC, wide-range Power Distribution Unit (PDU) can be mounted in
several configurations with the LXr 8500. One of these configurations is shown in
Figure 2-2. Others are listed and illustrated throughout Chapter 3.
How to Position the PDU
Count the receptacles needed for each unit in the rack, notice where the PDUs can
be most conveniently located, and decide whether to orient the PDU vertically or
horizontally.
Horizontal Mounting
of Two PDUs in
a Fully Utilized
Rack
Cable Guides
Mounted on the
Column Across
from the Door
Hinges
Examples of
Data Cable
Routes from
Server to
Connectors on
Other
Components
200-240 VAC Wide-
Range 10-Amp,
19-Inch Power
Distribution Unit,
Installed
Horizontally
Behind the Monitor
(Power Cord
Connections
to Equipment
Are Not
Illustrated
Here)
Data Cables
Routed
through
Cable
Management
Arm
200-240 VAC Wide-
Range 16-Amp
PDU Mounted
Horizontally
Behind the
Uninterruptible
Power Supply
Figure 2-2. Mounting a Pair of PDUs Horizontally (Rear View)