Chapter 3 Mount the Drive in the NetServer E 45 • If the drive is in a factory-provided tray, place the drive on a flat surface free from static electricity with the circuit board on the drive facing up. Remove the four screws that attach the drive to the tray and remove the drive. (These screws can be used to mount the drive in the HP NetServer E 45.) Step 2: Mount the Drive in the System To prepare to install the drive: • Turn off your system and the display. • Disconnect the power cords. • Detach any external cables. • Remove the cover from the HP NetServer. • Remove any hardware necessary to reach the cables or insert the drive. Consult Information Assistant on the HP NetServer Navigator CD-ROM for your system for specific instructions for removing components. If you are mounting the drive in shelf 5 or 6, continue with "Mount the Drive in Shelf 5 or 6" If you are mounting the drive in shelf 3 or 4, continue with "Mount the Drive in Shelf 3 or 4." Mount the Drive in Shelf 5 or 6 • Remove the rear cooling fan. • Align the four screw holes of the rear shelf with the four screw holes of the drive. • Loosely install all of the screws (provided with the drive), then tighten the screws to no more than eight inch-pounds (0.9 newton meters). • Carefully insert the fan wire fully into the drive bay. • Replace the rear cooling fan. Continue with Step 3. 25

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46

Chapter 3
Mount the Drive in the NetServer E 45
25
If the drive is in a factory-provided tray, place the drive on a flat surface
free from static electricity with the circuit board on the drive facing up.
Remove the four screws that attach the drive to the tray and remove the
drive. (These screws can be used to mount the drive in the HP NetServer E
45.)
Step 2: Mount the Drive in the System
To prepare to install the drive:
Turn off your system and the display.
Disconnect the power cords.
Detach any external cables.
Remove the cover from the HP NetServer.
Remove any hardware necessary to reach the cables or insert the drive.
Consult Information Assistant on the
HP NetServer Navigator CD-ROM
for your system for specific instructions for removing components.
If you are mounting the drive in shelf 5 or 6, continue with "Mount the Drive in
Shelf 5 or 6" If you are mounting the drive in shelf 3 or 4, continue with "Mount
the Drive in Shelf 3 or 4."
Mount the Drive in Shelf 5 or 6
Remove the rear cooling fan.
Align the four screw holes of the rear shelf with the four screw holes of the
drive.
Loosely install all of the screws (provided with the drive), then tighten the
screws to no more than eight inch-pounds (0.9 newton meters).
Carefully insert the fan wire fully into the drive bay.
Replace the rear cooling fan.
Continue with Step 3.