HP LH4r HP Ultra/Wide SCSI 4 GB and 9 GB Hard Disk Drive - Page 34
Delay Spin-Up, Motor Start Enable, Parity Disable, Reserved, Write Protect, Delay Time
View all HP LH4r manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 34 highlights
Appendix A Jumper Settings ID Description DS Delay Spin-Up On* Motor start up is delayed by the sum of the SCSI ID times 6 seconds after power is applied; i.e., Drive 0 spindle starts immediately, drive 1 starts after a 6 second delay, drive 2 starts after a 12 second delay, and so forth. Off Motor start up begins immediately after system power up, unless Motor Start Enable is on. If Motor Start Enable is on, it overrides this setting. ME Motor Start Enable On Drive spindle starts when the Start Unit command is received from the host system. If the Delay Spin-Up feature is on, the Delay Spin-Up feature is overridden. Off* Spindle starts immediately after power up. If Delay Spin-Up is on, it overrides this setting. PD Parity Disable On Parity checking and parity error reporting by the drive is disabled. Off* Parity checking and parity error reporting by the drive is enabled. The drive checks for parity and reports the results of parity checking to the host system. RES Reserved This pin set is not used and must remain as set at the factory. WP Write Protect On The drive is write protected. Off* The drive is not write protected. 12/6 Delay Time On The delay spin-up is 12 seconds. Off* The delay spin-up is 6 seconds. * Default NOTE Jumpers are "off," when the jumper is not installed (no electrical connection) or "on," when the jumper is in place (completing the electrical connection). 30