HP Latex 110 Introductory information - Page 8

Several blocked nozzles have been detected in the optimizer printhead. If print

Page 8 highlights

Error code Recommendation 16.14:10 16.84:03, 16.85:03 21:13 21.2:10 21.5:03 25.n:10 (where n = the ink cartridge number) 27.1:00 27.n:01 (where n = the printhead slot number) 29:00 29:01 29.1:01 29.2:00 Curing temperature sensor measurement out of range (temperature sensor 4 failed or not connected). 1. Turn off the printer. 2. Check that the ambient temperature is within printer specifications (15-35°C). 3. Check that the electronic enclosures at the rear of the printer are properly ventilated. 4. Turn on the printer. Air curtain resistor out of range. Check that the air curtain fans (at the front of the curing module) are working and unblocked. Unable to move the maintenance cartridge along its whole path. 1. Turn off the printer. 2. While the printer is off, remove the printhead maintenance cartridge manually. 3. Make sure that the printhead maintenance cartridge path is clear. Remove any visible obstacles (paper, plastic parts, and so on) restricting the movement. 4. Reinstall the printhead maintenance cartridge. 5. Turn on the printer. 6. If the error persists, replace the printhead cleaning cartridge. Printhead cleaning cartridge error. 1. Turn off the printer. 2. Remove and reinsert the printhead cleaning cartridge. 3. Turn on the printer. 4. If the error persists, replace the printhead cleaning cartridge. The part that advances the printhead maintenance cartridge web wipe is blocked. 1. Turn off the printer. 2. Manually remove and insert the printhead maintenance cartridge. 3. Turn on the printer. 4. If the error persists, replace the printhead cleaning cartridge. A possible error in the ink cartridge pressure sensor has been detected. The ink level reported may not be accurate. Call your service representative if feasible. Several blocked nozzles have been detected in the optimizer printhead. If print quality is not acceptable, clean or replace the printhead. A large number of blocked nozzles have been detected in one or more printheads. Calibration may have failed due to low printhead performance. Clean all the printheads and check their status. The printhead cleaning cartridge (part number CZ681A ) is almost full. It will need to be replaced soon. The printhead cleaning cartridge is not inserted correctly. 1. Open the printhead cleaning cartridge door on the right of the printer. 2. Make sure that the printhead cleaning cartridge is correctly seated, then close the door. 3. If the error persists, replace the printhead cleaning cartridge. Unable to track the printhead cleaning cartridge status. Check, visually, that the maintenance cartridge has a correct status pattern on it. Unable to advance the printhead cleaning roll. Replace the printhead cleaning cartridge. 7 Introductory Information

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12

Introductory Information
7
Error code
Recommendation
16.14:10
Curing temperature sensor measurement out of range (temperature sensor 4
failed or not connected).
1.
Turn o±
the printer.
2.
Check that the ambient temperature is within printer specifications (15–35°C).
3.
Check that the electronic enclosures at the rear of the printer are properly
ventilated.
4.
Turn on the printer.
16.84:03, 16.85:03
Air curtain resistor out of range.
Check that the air curtain fans (at the front of the
curing module) are working and unblocked.
21:13
Unable to move the maintenance cartridge along its whole path.
1.
Turn o±
the printer.
2.
While the printer is o±
, remove the printhead maintenance cartridge manually.
3.
Make sure that the printhead maintenance cartridge path is clear. Remove any
visible obstacles (paper, plastic parts, and so on) restricting the movement.
4.
Reinstall the printhead maintenance cartridge.
5.
Turn on the printer.
6.
If the error persists, replace the printhead cleaning cartridge.
21.2:10
Printhead cleaning cartridge error.
1.
Turn o±
the printer.
2.
Remove and reinsert the printhead cleaning cartridge.
3.
Turn on the printer.
4.
If the error persists, replace the printhead cleaning cartridge.
21.5:03
The part that advances the printhead maintenance cartridge web wipe is blocked.
1.
Turn o±
the printer.
2.
Manually remove and insert the printhead maintenance cartridge.
3.
Turn on the printer.
4.
If the error persists, replace the printhead cleaning cartridge.
25.n:10 (where n = the ink
cartridge number)
A possible error in the ink cartridge pressure sensor has been detected. The ink
level reported may not be accurate. Call your service representative if feasible.
27.1:00
Several blocked nozzles have been detected in the optimizer printhead. If print
quality is not acceptable, clean or replace the printhead.
27.n:01 (where n = the printhead
slot number)
A large number of blocked nozzles have been detected in one or more printheads.
Calibration may have failed due to low printhead performance. Clean all the
printheads and check their status.
29:00
The printhead cleaning cartridge (part number CZ681A ) is almost full. It will need
to be replaced soon.
29:01
The printhead cleaning cartridge is not inserted correctly.
1.
Open the printhead cleaning cartridge door on the right of the printer.
2.
Make sure that the printhead cleaning cartridge is correctly seated, then close
the door.
3.
If the error persists, replace the printhead cleaning cartridge.
29.1:01
Unable to track the printhead cleaning cartridge status. Check, visually, that the
maintenance cartridge has a correct status pattern on it.
29.2:00
Unable to advance the printhead cleaning roll. Replace the printhead cleaning
cartridge.