HP Latex 1500 Site Preparation Guide - Page 11
Power distribution unit (PDU), Power specifications
View all HP Latex 1500 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 11 highlights
NOTE: Remember that you are required to follow the local laws, regulations, and standards that apply to the electrical installation of your printer. NOTE: The printer is not supplied with any power cable. Power distribution unit (PDU) The PDU must be rated to meet the power requirements of the printer, and should be in accordance with the Electrical Code requirements of the local jurisdiction of the country where the equipment is installed. Power specifications Configuration 1: 380-415 V line-to-line three-phase configuration Power specifications Number of power wires Input voltage (line to line) Input frequency 5 (L1/L2/L3/N/PE) 380-415 V 50/60 Hz Power consumption (typical) 8-10 kW Maximum load current (per phase) 30 A Branch circuit-breaker specifications Three-phase 4 poles, 32/40 A Power-cable specifications Configuration Wire Terminals External diameter range 5 wires, L1/L2/L3/N/PE Strained Cu minimum, 6mm2 or 10AWG Lines, ferrule terminals, PE, M8 ring terminal 22.0-33.0 mm Configuration 2: 200-240 V line-to-line three-phase configuration Power specifications Number of power wires) 4 (L1/L2/L3/PE) ENWW System operation requirements 7