HP Latex 1500 Site Preparation Guide - Page 12

Configuration 3: 380–415 V line-to-line three-phase configuration with single- phase control

Page 12 highlights

Power specifications (continued) Input voltage (line to line) Input frequency Power consumption (typical) Maximum load current (per phase) 200-240V 50/60 Hz 8-10 kW 48 A Branch circuit-breaker specifications Three-phaseP 3 poles, 50/60 A AC Power-cable specifications Configuration Wire Terminals External diameter range 4 wires, L1/L2/L3/PE Strained Cu minimum, 10 mm² or 6 AWG Lines, ferrule terminals, PE, M8 ring terminal 22.0-33.0 mm Configuration 3: 380-415 V line-to-line three-phase configuration with single- phase control Power specifications Three-phase line Single-phase control Number of power wires Input voltage (line to line) 5 (L1/L2/L3/N/PE) 380-415 V 3 (L/N/PE) 100-240 V Input frequency 50/60 Hz 50/60 Hz Power consumption (typical) Maximum load current (per phase) 8-10 kW 30 A 0.5 kW 10 A Branch circuit-breaker specifications Three-phase Two-phase control 4 poles,32/40 A 2 poles, 15/16/20 A 8 Chapter 2 Site preparation ENWW

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28

Power specifications (continued)
Input voltage (line to line)
200–240V
Input frequency
50/60 Hz
Power consumption (typical)
8–10 kW
Maximum load current (per phase)
48 A
Branch circuit-breaker specifications
Three-phaseP
3 poles, 50/60 A
AC Power-cable specifications
Configuration
4 wires, L1/L2/L3/PE
Wire
Strained Cu minimum, 10 mm² or 6 AWG
Terminals
Lines, ferrule terminals, PE, M8 ring terminal
External diameter range
22.0–33.0 mm
Configuration 3: 380–415 V line-to-line three-phase configuration with single- phase control
Power specifications
Three-phase line
Single-phase control
Number of power wires
5 (L1/L2/L3/N/PE)
3 (L/N/PE)
Input voltage (line to line)
380–415 V
100–240 V
Input frequency
50/60 Hz
50/60 Hz
Power consumption (typical)
8–10 kW
0.5 kW
Maximum load current (per phase)
30 A
10 A
Branch circuit-breaker specifications
Three-phase
4 poles,32/40 A
Two-phase control
2 poles, 15/16/20 A
8
Chapter 2
Site preparation
ENWW