HP Latex 2700 User Guide 4 - Page 14

Printcare diagnostics

Page 14 highlights

4 Printcare diagnostics The following sections provide details for this topic. Diagnostics for operator (HP Latex 1500 Printer) You can run these diagnostics only if the roll-to-freefall kit is installed. Roll-to-freefall kit Alert Recommendation 41011 Electronic check This diagnostic allows you to check the connectivity with the electronic parts in the kit. 41012 Sensors check 41013 MF and MO motors check This diagnostic allows you to check the status of the sensors in the kit (tension-roller latch, tensionroller lever, substrate-collector sensor). This diagnostic makes automatic checks on the substrate floor motor and substrate output motor. Diagnostics for operator (HP Latex 2700 printer series) You can run these diagnostics only if the roll-to-freefall kit is installed. Roll-to-freefall kit Alert Recommendation 41102 Electronic check 41103 Sensors check This diagnostic checks the electronic connections required for the roll-to-freefall kit to work: ● Power Supply Unit 1 (PSU 1) is in range. ● Fuse for the PSU 1 is working. ● Connection to the e-box interconnect PCA is working. This diagnostic checks that the following sensors are working properly: ● Loading-table-latch sensors ● Take-up-reel sensor ● Pinch-lever switch sensor 41104 Media Floor motor check It checks the performance of the sensors when pulling and pushing the latches and levers, and blocking and unblocking the substrate-collector sensors. When the sensors are working correctly, it shows the changes in sensor status. This diagnostic performs a direction test of the substrate floor motor and the substrate front motor. Printcare diagnostics 11

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16

Printcare diagnostics
4
The following sections provide details for this topic.
Diagnostics for operator (HP Latex 1500 Printer)
You can run these diagnostics only if the roll-to-freefall kit is installed.
Roll-to-freefall kit
Alert
Recommendation
41011 Electronic check
This diagnostic allows you to check the connectivity with the electronic parts in the kit.
41012 Sensors check
This diagnostic allows you to check the status of the sensors in the kit (tension-roller latch, tension-
roller lever, substrate-collector sensor).
41013 MF and MO motors check
This diagnostic makes automatic checks on the substrate floor motor and substrate output motor.
Diagnostics for operator (HP Latex 2700 printer series)
You can run these diagnostics only if the roll-to-freefall kit is installed.
Roll-to-freefall kit
Alert
Recommendation
41102 Electronic check
This diagnostic checks the electronic connections required for the roll-to-freefall kit to work:
Power Supply Unit 1 (PSU 1) is in range.
Fuse for the PSU 1 is working.
Connection to the e-box interconnect PCA is working.
41103 Sensors check
This diagnostic checks that the following sensors are working properly:
Loading-table-latch sensors
Take-up-reel sensor
Pinch-lever switch sensor
It checks the performance of the sensors when pulling and pushing the latches and levers, and
blocking and unblocking the substrate-collector sensors. When the sensors are working correctly, it
shows the changes in sensor status.
41104 Media Floor motor check
This diagnostic performs a direction test of the substrate floor motor and the substrate front motor.