HP MSA2312sa HP StorageWorks 2000 G2 Modular Smart Array reference guide (5009 - Page 92

event only applies to non-Active-Active, been inserted from another enclosure.

Page 92 highlights

Table 14 Event code descriptions and recommended actions (continued) Event Event type Description code Recommended action 59 Warning or The controller detected an error while • For warning events that indicate a disk is informational communicating with the specified SCSI bad, replace that disk. device. The error was detected by the controller, not the disk. This event is logged as a warning for parity errors, and as informational for other errors. • For warning events that indicate an expansion module is bad, replace that expansion module. 60 Informational A disk channel was reset from another initiator or target. 61 Critical A serious error, which might indicate hardware failure, occurred while communicating on the specified disk channel. The controller will attempt to recover. • If the controller recovers, no action is required. • View other logged events to determine other action to take. 62 Informational A spare disk has failed. Replace the failed disk. 65 Critical An uncorrectable ECC error occurred on the buffer memory on startup. The controller is automatically restarted and-if it was operating in active-active mode (i.e., independent cache performance mode was disabled)-its cache data is restored from the partner controller's cache. 67 Informational The controller has identified a new disk or group of disks that constitute a vdisk and has taken ownership of the vdisk. This can happen when disks containing data have been inserted from another enclosure. This event only applies to non-Active-Active controllers. 68 Informational Controller is in a shut-down state. 69 Critical Enclosure reported a general failure. Check the controller module or expansion module for problems such as not being fully inserted, and for bad cables. 71 Informational The controller has started or completed failing over. 72 Informational (Active-active environment) After failover, recovery has started or has completed. 73 Informational (Active-active environment) The two controllers are communicating with each other and cache redundancy is enabled. 74 Informational The FC loop ID for the specified vdisk was changed to be consistent with the IDs of other vdisks. This can occur when disks containing a vdisk are inserted from an enclosure having a different FC loop ID. This event is also logged by the new owning controller after vdisk ownership is changed. 92 Event code reference

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118

92
Event code reference
59
Warning or
informational
The controller detected an error while
communicating with the specified SCSI
device. The error was detected by the
controller, not the disk. This event is logged
as a warning for parity errors, and as
informational for other errors.
For warning events that indicate a disk is
bad, replace that disk.
For warning events that indicate an
expansion module is bad, replace that
expansion module.
60
Informational
A disk channel was reset from another
initiator or target.
61
Critical
A serious error, which might indicate
hardware failure, occurred while
communicating on the specified disk
channel. The controller will attempt to
recover.
If the controller recovers, no action is
required.
View other logged events to determine
other action to take.
62
Informational
A spare disk has failed.
Replace the failed disk.
65
Critical
An uncorrectable ECC error occurred on the
buffer memory on startup. The controller is
automatically restarted and—if it was
operating in active-active mode (i.e.,
independent cache performance mode was
disabled)—its cache data is restored from the
partner controller’s cache.
67
Informational
The controller has identified a new disk or
group of disks that constitute a vdisk and has
taken ownership of the vdisk. This can
happen when disks containing data have
been inserted from another enclosure. This
event only applies to non-Active-Active
controllers.
68
Informational
Controller is in a shut-down state.
69
Critical
Enclosure reported a general failure.
Check the controller module or expansion
module for problems such as not being fully
inserted, and for bad cables.
71
Informational
The controller has started or completed
failing over.
72
Informational
(Active-active environment)
After failover, recovery has started or has
completed.
73
Informational
(Active-active environment)
The two controllers are communicating with
each other and cache redundancy is
enabled.
74
Informational
The FC loop ID for the specified vdisk was
changed to be consistent with the IDs of
other vdisks. This can occur when disks
containing a vdisk are inserted from an
enclosure having a different FC loop ID.
This event is also logged by the new owning
controller after vdisk ownership is changed.
Table 14
Event code descriptions and recommended actions (continued)
Event
code
Event type
Description
Recommended action