Page 99 highlights
Table 14 Event code descriptions and recommended actions (continued) Event Event type Description code Recommended action 214 Informational The creation of snapshots is complete. The number of snapshots is specified. 215 Informational A previously created batch of snapshots is now committed and ready for use. The number of snapshots is specified. 217 Critical A super-capacitor failure has occurred on the A service technician must replace the controller. super-capacitor pack on the controller reporting this event. 218 Warning The super-capacitor pack is near end of life. A service technician must replace the super-capacitor pack on the controller reporting this event. 219 Informational Utility priority has changed. 220 Informational Master volume rollback operation has started. 221 Informational Snapshot reset is completed. 222 Informational Setting of the policy for the snap pool is complete. Policy is the action to be taken when the snap pool hits the threshold level. 223 Informational The threshold level for the snap pool has been set. Each snap pool has three policy levels that notify you when the snap pool is reaching decreasing capacity. Each policy level has an associated policy that specifies system behavior when the threshold is reached. 224 Informational A background master volume rollback operation has completed. 225 Critical Background master write copy-on-write operation has failed. There was an internal I/O error. Could not complete the write operation to the disk. A probable hardware failure has prevented the software from operating successfully. Isolate and replace and failed hardware components. Once the hardware issues have been corrected, it might be necessary to delete all snapshots and restart the controller. 226 Critical A background master volume rollback failed Make sure the snap pool and the vdisk on to start due to inability to initialize the snap which this volume exists are online. Restart pool. All rollback is in a suspended state. the rollback operation. 227 Critical Failure to execute rollback for a particular portion of the master volume. Restart the rollback operation. 228 Critical Background rollback for a master volume failed to end due to inability to initialize the snap pool. All rollback is in a suspended state. Make sure the snap pool and the vdisk on which this volume exists are online. Restart the rollback operation. 229 Warning The snap pool has reached the snap pool warning threshold. The user can set up the policy for the snap pool. HP StorageWorks 2000 G2 Modular Smart Array Reference Guide 99