HP Pavilion 13-p100 Maintenance and Service Guide - Page 46

Battery, that secure the battery to the dock.

Page 46 highlights

Battery Description 3-cell, 32-WHr, 2.96-AH battery Spare part number 725607-001 Before removing the battery, follow these steps: 1. Shut down the computer. If you are unsure whether the computer is off or in Hibernation, turn the computer on, and then shut it down through the operating system. 2. Disconnect all external devices connected to the computer. 3. Disconnect the power from the computer by first unplugging the power cord from the AC outlet and then unplugging the AC adapter from the computer. 4. Disconnect the tablet from the keyboard dock (see Releasing the tablet from the keyboard dock on page 30). 5. Remove the base enclosure (see Base enclosure on page 31). Remove the battery: 1. Remove the six Phillips PM2.0×4.0 screws (1) that secure the battery to the dock. 2. Remove the two PM2.5×5.0 screws (2) that secure the battery to the dock. These screws also secure the hinges. 3. Disconnect the battery connector (3). 4. Remove the battery (4) from the dock. 36 Chapter 5 Removal and replacement procedures for Authorized Service Provider parts

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97

Battery
Description
Spare part number
3-cell, 32-WHr, 2.96-AH battery
725607-001
Before removing the battery, follow these steps:
1.
Shut down the computer. If you are unsure whether the computer is off or in Hibernation, turn
the computer on, and then shut it down through the operating system.
2.
Disconnect all external devices connected to the computer.
3.
Disconnect the power from the computer by first unplugging the power cord from the AC outlet and
then unplugging the AC adapter from the computer.
4.
Disconnect the tablet from the keyboard dock (see
Releasing the tablet from the keyboard dock
on page
30
).
5.
Remove the base enclosure (see
Base enclosure
on page
31
).
Remove the battery:
1.
Remove the six Phillips PM2.0×4.0 screws
(1)
that secure the battery to the dock.
2.
Remove the two PM2.5×5.0 screws
(2)
that secure the battery to the dock. These screws also secure the
hinges.
3.
Disconnect the battery connector
(3)
.
4.
Remove the battery
(4)
from the dock.