HP ProLiant 1500 ProLiant Server Troubleshooting Guide - Page 229
Array - S.M.A.R.T., Backup ROM has
View all HP ProLiant 1500 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 229 highlights
POST Error Messages Table C-13: 1700 Series POST Error Messages continued Error Code Audible Beeps Probable Source of Problem 1713-Slot z Drive Array Controller Redundant ROM Reprogramming Failure Replace the controller if this error persists after restarting system. None Flash ROM is going bad. Controller detected a checksum failure but is unable to reprogram the backup ROM. 1714-Slot z Drive Array Controller Redundant ROM Checksum Error Backup ROM has automatically been activated. Check firmware version. None Controller flash operation interrupted by powercycle, or flash ROM may be going bad. 1720-Slot X Drive Array - S.M.A.R.T. Hard Drive(s) Detect Imminent Failure SCSI: Port Y: SCSI ID Z. None Hard drive predictive failure condition detected. Action Replace controller when possible, or try upgrading firmware using Options ROMPaq. Controller has detected a ROM checksum error and automatically switched to the backup ROM image. Upgrade controller firmware using Options ROMPaq if this backup ROM image is a lower version than that originally running. The indicated drive has reported a SMART predictive failure condition. It may fail at some time in the future. • If this drive is part of a non-fault-tolerant configuration, back up all data before replacing the drive and restore all data afterward. • If this drive is part of a fault-tolerant configuration, do not replace this drive unless all other drives in the array are online. continued HP Servers Troubleshooting Guide C-49