HP ProLiant 1500 ProLiant Server Troubleshooting Guide - Page 242
Replace I/O board., Array Drive Failure.
View all HP ProLiant 1500 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 242 highlights
POST Error Messages Table C-13: 1700 Series POST Error Messages continued Error Code Audible Beeps Probable Source of Problem 1783-Slot X Drive Array Controller Failure. None Bad controller. If this message is displayed after Options ROMPaq is run, problems may have occurred while attempting to flash the ROM. 1783-Intelligent Drive Array Controller Failure None Integrated Array Controller firmware is corrupt, or IAC is bad or has failed. 1784-Slot X Drive Array Drive Failure. The following SCSI drive(s) should be replaced: SCSI Port Y: SCSI ID Z: None Defective drive and/or SCSI cables detected. Action Reseat the array accelerator module if detached. Try reseating the controller in the PCI slot. Otherwise, replace the array controller. 1. Be sure that integrated array controller ROM firmware is up to date. 2. Replace I/O board. Check for loose cables. Be sure that all drives are fully seated in drive bay slots. Replace defective drive X and/or cable(s). continued C-62 HP Servers Troubleshooting Guide