HP ProLiant 1500 ProLiant Server Troubleshooting Guide - Page 244
Port Y: SCSI ID Z, System in Interim Data
View all HP ProLiant 1500 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 244 highlights
POST Error Messages Table C-13: 1700 Series POST Error Messages continued Error Code Audible Beeps Probable Source of Problem 1786-Slot 1 Drive Array Recovery Needed. The following SCSI drive(s) need Automatic Data Recovery: SCSI Port Y: SCSI ID Z None System in Interim Data Recovery mode. Previously-failed or replacement drive has not yet been rebuilt. Select F1 to continue with recovery of data to drive. Select F2 to continue without recovery of data to drive. -Or- Slot 1 Drive Array Recovery Needed. Automatic Data Recovery Previously Aborted! The following SCSI drive(s) need Automatic Data Recovery: SCSI Port Y: SCSI ID Z Select F1 to retry Automatic Data Recovery to drive. Select F2 to continue without starting Automatic Data Recovery. Action Press the F1 key to allow Automatic Data Recovery to begin. Data is automatically restored to drive X when the drive has been replaced or seems to be working. -Or- 1. Press the F2 key for the system to continue to operate in the Interim Data Recovery mode. The previously aborted version of the 1786 POST message is displayed if the previous rebuild attempt was aborted for any reason. 2. Run Array Diagnostic Utility (ADU) for more information. If the replacement drive was failed, try using another replacement drive. -Or- If rebuild was aborted due to a read error from another physical drive in the array, back up all readable data on the array, run Diagnostics Surface Analysis, and then restore your data. continued C-64 HP Servers Troubleshooting Guide