HP R1500 UPS R6000 Models User Guide - Page 32

Status, UPS Status + Receptacle Status, UPS Status + Active Alarm Count, Table 3-2

Page 32 highlights

LCD Configuration and Status Status Select Status on the Main Menu and press the Enter button to view the status or active alarms for the UPS. Main Menu → Status UPS Status + Receptacle Status Select UPS Status + Receptacle Status from the Status menu to view information about the system. The following LCD display example shows that the UPS has detected no problems. Load segments 1, 4, and 5 are on. Load segments 2 and 3 are off. System Normal ON: 1 - - 4 5 UPS Status + Active Alarm Count Select UPS Status + Active Alarm Count from the Status menu to view the number of current alarms. In this example, the UPS has detected no problems and there are no alarms. System Normal 0 Alarms Table 3-2: Active Alarm Count Options LCD Display On Battery x Alarms On Bypass x Alarms Load Power Off x Alarms Load Power On x Alarms Overload x Alarms Explanation The UPS has switched from utility voltage input to battery power. The UPS has been placed in Bypass mode. The power feeding the UPS-protected devices has terminated. Utility power has been restored to the devices backed up by the UPS. There are too many loads attached to the UPS. HP Uninterruptible Power System R6000 Models User Guide 3-5

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68

LCD Configuration and Status
HP Uninterruptible Power System R6000 Models User Guide
3-5
Status
Select Status on the Main Menu and press the Enter button to view the status or active alarms
for the UPS.
Main Menu
Status
UPS Status + Receptacle Status
Select UPS Status + Receptacle Status from the Status menu to view information about the
system. The following LCD display example shows that the UPS has detected no problems.
Load segments 1, 4, and 5 are on. Load segments 2 and 3 are off.
System Normal
ON:
1 - - 4 5
UPS Status + Active Alarm Count
Select UPS Status + Active Alarm Count from the Status menu to view the number of current
alarms. In this example, the UPS has detected no problems and there are no alarms.
System Normal
0 Alarms
Table 3-2:
Active Alarm Count Options
LCD Display
Explanation
On Battery
x
Alarms
The UPS has switched from utility voltage input to battery power.
On Bypass
x
Alarms
The UPS has been placed in Bypass mode.
Load Power Off
x
Alarms
The power feeding the UPS-protected devices has terminated.
Load Power On
x
Alarms
Utility power has been restored to the devices backed up by the UPS.
Overload
x
Alarms
There are too many loads attached to the UPS.