HP Scitex FB10000 Geffen TS Error 67022 - Page 2

Troubleshooting Flowchart, Error ID: 67022: Safety - Rear rising media detector activated loader side

Page 2 highlights

Error ID: 67022: Safety - Rear rising media detector activated (loader side) Troubleshooting Flowchart Open UV door and verify that flap is moving smoothly by No tilting it forward and backward Error message(67023) vanish Is flap moving smoothly Yes Is sensor Led on ? No Open REC door Identify the mechanical problem No that caused the flap not moving smoothly Recalibrate the flap till the bracket will Yes cross the fork sensor and the led will be off Error messages (67022-67025) Push the Refresh button Open UV door and take stuck media out. Close door ,push "Reset" No button and "Refresh" button Did the Error message(67023) disappear ? Yes Yes Unload substrate Are green LEDs 9 & 10 of the 2SDI3 B&R No module on ? Yes Perform Z calibration validation and afterwards perform Rising Media calibration Is the two connect well ? Yes Replace the sensor Reconnect the No sensor and verify that the green led is on FB10000 Error Messages Troubleshooting Check substrate quality Print Close door and push "Reset" button Top Flowchart 2

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9

Error ID: 67022: Safety - Rear rising media detector activated (loader side)
FB10000 Error Messages Troubleshooting
Troubleshooting Flowchart
Error messages
(67022-67025)
Did the Error
message(67023)
disappear ?
Unload substrate
Yes
Check substrate
quality
Print
Open UV door and
take stuck media
out. Close door
,push “Reset”
button and
“Refresh” button
No
Error
message(67023)
vanish
Yes
Open UV door and
verify that
flap is
moving smoothly by
tilting it forward
and backward
No
Is flap moving
smoothly
Identify the
mechanical problem
that caused the flap
not moving
smoothly
No
Is sensor Led on
?
Yes
Recalibrate the flap
till the bracket will
cross the fork
sensor and the led
will be off
Yes
Open REC door
No
Are green LEDs 9
& 10 of the
2SDI3 B&R
module on ?
Push the Refresh
button
Is the two
connect well ?
No
Replace the sensor
Yes
Perform Z
calibration
validation and
afterwards perform
Rising Media
calibration
Yes
Close door and push
“Reset” button
Reconnect the
sensor and verify
that the green led is
on
No
Top
Flowchart
2