HP StorageWorks 4/64 Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 359
routes two port together and spins frames between them.
View all HP StorageWorks 4/64 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 359 highlights
miniCycle 2 Examples -spd_mode mode Specifies the speed mode for the test. This parameter is only used for Bloom and Condor ASIC-based products, for which this parameter controls the speed at which each port operates. For 1 Gbit/sec-only products, this parameter is ignored. The exact operation of modes 5 through 8 depends on the loopback mode selected. When speed modes 5 through 8 are used with cables, they must be connected EVEN->ODD or the test fails. 0 Run test at 1 Gbit/sec, 2 Gbit/sec, and 4 Gbit/sec (default). 1 Set all port speeds to lock at 1 Gbit/sec. 2 Set all port speeds to lock at 2 Gbit/sec. 4 Set all port speeds to lock at 4 Gbit/sec. For -lb_mode set to 1, the following speed modes are available to test the speed negotiation. 3 Set all even ports' speed for auto-negotiate. Set all odd ports' speed for 1 Gbit/sec. 4 Set all even ports' speed for auto-negotiate. Set all odd ports' speed for 2 Gbit/sec. 5 Set all odd ports' speed for auto-negotiate. Set all even ports' speed for 1 Gbit/sec. 6 Set all odd ports' speed for auto-negotiate. Set all even ports' speed for 2 Gbit/sec. For -lb_mode set to 2, the following speed modes are available to test FIFO underrun. 3,5 Set all even ports' speed for 2 Gbit/sec. Set all odd ports' speed for 1 Gbit/sec. 4,6 Set all even ports' speed for 1 Gbit/sec. Set all odd ports' speed for 2 Gbit/sec. -splb_mode 0 | 1 Specifies a special loopback mode for minicycle.The regular minicycle test routes two port together and spins frames between them. In splb_mode, ports are not routed. Each port spins frames to themselves. This test resembles a spinning version of porLoopBackTest. Note that in splb_mode, the test will do one pass only on path 8. splb_mode is either on (1) or off (0). The default is off (0). -ports itemlist Specifies a list of blade ports to test. By default, all the blade ports in the specified slot (--slot) are used. Refer to itemlist for further details. If all ports in the ASIC pair are not specified, only paths between selected ports are tested. ASIC-pair 0: -ports 0-15 ASIC-pair 1: -ports 16-31 ASIC-pair 2: -ports 32-47 ASIC-pair 3: -ports 48-63 To run a functional test on slot 1 using external (SERDES) loopback: switch:admin> minicycle --slot 1 -lb_mode 2 Fabric OS Command Reference 333 53-1000599-01