HP StorageWorks 4/64 Brocade Fabric OS Command Reference Guide v6.0.0 (53-1000 - Page 550
Invalid ARB., statistics. Use
View all HP StorageWorks 4/64 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 550 highlights
2 portStatsShow er_crc_good_eof CRC error with good EOF (platform and port specific). er_inv_arb Invalid ARB. open Number of times the FL_Port entered OPEN state. transfer Number of times the FL_Port entered TRANSFER state. opened Number of times the FL_Port entered OPENED state. starve_stop Loop tenancies stopped due to starvation. fl_tenancy Number of times FL_Port had loop tenancy. nl_tenancy Number of times NL_Port had loop tenancy. zero_tenancy Number of times zero tenancy occurred. The execution of this command is subject to Admin Domain restrictions that may be in place. Operands This command has the following operands: slotnumber For bladed systems only, specifies the slot number of the port to be displayed, followed by a slash (/). [ge]portnumber Specifies a port number to be configured, relative to its slot for bladed systems. Specify the optional ge option to display the GbE port hardware statistics. Use switchShow to display a list of valid ports. ge Displays the GbE statistics. ip Displays all the GbE port statistics related to IP addresses that are on (not zero). Optionally, use ipaddress to display statistics for the specified IP address. fcip Displays the GbE statistics on all FCIP tunnels. Optionally, use tunnelnumber to display statistics for the specified FCIP tunnel. Examples To display the basic set of statistics for a port: switch:admin> portstatsshow 13 stat_wtx 0 stat_wrx 0 stat_ftx 0 stat_frx 0 stat_c2_frx 0 stat_c3_frx 0 stat_lc_rx 0 stat_mc_rx 0 stat_mc_to 0 stat_mc_tx 0 tim_rdy_pri 0 tim_txcrd_z 0 er_enc_in 0 er_crc 0 er_trunc 0 er_toolong 0 er_bad_eof 0 er_enc_out 0 er_bad_os 0 er_c3_timeout 0 er_c3_dest_unreach 0 unreachable 4-byte words transmitted 4-byte words received Frames transmitted Frames received Class 2 frames received Class 3 frames received Link control frames received Multicast frames received Multicast timeouts Multicast frames transmitted Time R_RDY high priority Time BB credit zero Encoding errors inside of frames Frames with CRC errors Frames shorter than minimum Frames longer than maximum Frames with bad end-of-frame Encoding error outside of frames Invalid ordered set Class 3 frames discarded due to timeout Class 3 frames discarded due to destination 524 Fabric OS Command Reference 53-1000599-01