HP StorageWorks Modular Smart Array 1000 HP StorageWorks 1000/1500 Modular Sma - Page 19

Using the Support Software CD (NetWare), <rpm filename&gt

Page 19 highlights

3. Browse the contents of the CD to locate and read the readme.txt file, which includes notes and information about the CD. 4. To update the HBA driver: IMPORTANT: Secure Path environments must uninstall Secure Path prior to updating HBA drivers and must reinstall Secure Path after the new HBA drivers are installed. NOTE: To build an HBA driver from source code or manually patch the Linux kernel, refer to the Readme.txt file in the /opt/hp/src/hp_qla2x00src directory on the Linux server. a. Navigate to the /RDP/Linux/ directory on the CD. b. List the contents of the directory and navigate to either the Emulex or QLogic directory, depending on the maker of your HBA. c. Change to the CD directory for your operating system version and list the contents of the directory. d. Enter the following command to install the new HBA driver: ./INSTALL -f 5. To update the ACU: a. Uninstall any previous version of ACU. b. From the console, navigate to the /ACU/Linux/x86 directory on the CD. c. List the contents of the directory and identify the ACU installation rpm file for your environment. d. Enter the following command to install/update the ACU: rpm -Uvh (Where is the name of the ACU installation rpm file.) NOTE: Warning messages regarding driver version dependencies may be displayed. These messages do not affect the MSA and may safely be ignored. e. Start the ACU and verify your settings. 6. Remove the Support Software CD from the CD-ROM drive, and then restart the server. 7. Repeat the steps in this section on each server with access to the MSA. 8. If necessary, reconnect the MSA to the SAN. Using the Support Software CD (NetWare) 1. With the HBAs installed in the server, apply power, start your NetWare operating system, and log on as a user with administrative rights. 2. Insert the MSA Support Software CD into the CD-ROM drive of the server, and then mount the CD-ROM. 3. Browse the contents of the CD to locate and read the readme.txt file, which includes notes and information about the CD. 4. To update the HBA driver: a. Enter the following command: 1000/1500 Modular Smart Array firmware updating guide 19

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40

3.
Browse the contents of the CD to locate and read the
readme.txt
le, which includes notes and
information about the CD.
4.
To update the HBA driver:
IMPORTANT:
Secure Path environments must uninstall Secure Path prior to updating HBA drivers and
must reinstall Secure Path after the new HBA drivers are installed.
NOTE:
To build an HBA driver from source code or manually patch the Linux kernel, refer to the
Readme.txt
le in the
/opt/hp/src/hp_qla2x00src
directory on the Linux server.
a.
Navigate to the
/RDP/Linux/
directory on the CD.
b.
List the contents of the directory and navigate to either the Emulex or QLogic directory,
depending on the maker of your HBA.
c.
Change to the CD directory for your operating system version and list the contents of the
directory.
d.
Enter the following command to install the new HBA driver:
./INSTALL —f
5.
To update the ACU:
a.
Uninstall any previous version of ACU.
b.
From the console, navigate to the
/ACU/Linux/x86
directory on the CD.
c.
List the contents of the directory and identify the ACU installation rpm
le for your environment.
d.
Enter the following command to install/update the ACU:
rpm -Uvh
<rpm filename>
(Where
<rpm
lename>
is the name of the ACU installation rpm
le.)
NOTE:
Warning messages regarding driver version dependencies may be displayed. These
messages do not affect the MSA and may safely be ignored.
e.
Start the ACU and verify your settings.
6.
Remove the Support Software CD from the CD-ROM drive, and then restart the server.
7.
Repeat the steps in this section on each server with access to the MSA.
8.
If necessary, reconnect the MSA to the SAN.
Using the Support Software CD (NetWare)
1.
With the HBAs installed in the server, apply power, start your NetWare operating system, and log on
as a user with administrative rights.
2.
Insert the MSA Support Software CD into the CD-ROM drive of the server, and then mount the
CD-ROM.
3.
Browse the contents of the CD to locate and read the
readme.txt
le, which includes notes and
information about the CD.
4.
To update the HBA driver:
a.
Enter the following command:
1000/1500 Modular Smart Array
rmware updating guide
19