HP StorageWorks Modular Smart Array 1000 HP StorageWorks 1000/1500 Modular Sma - Page 30
Msa> Flash Firmware Msav686b272.bin, Msa> Set Controller $1$gga400.
![]() |
View all HP StorageWorks Modular Smart Array 1000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 30 highlights
7. Enter the following command to open the MSA_UTIL firmware flash program: RUN SYS$ETC:MSA_UTIL 8. Enter the show controller command to see a list of MSA controllers on the SAN: Example command and response: MSA> SHOW CONTROLLER/BRIEF A default controller is not set. All matching controllers displayed: Controller: $1$GGA400: MSA1xxx (C) COMPAQ P56350B9IMX025 Software 3.36 NODE_ID = 500805f3-0001b290 Controller Identifier: 400 Current Redundancy mode: Active/Standby Current Role: Active Controller: $1$GGA401: Controller Identifier: 401 MSA1xxx (C) COMPAQ P56350B9IN20HW NODE_ID = 500805f3-0001b290 Current Redundancy mode: Active/Standby Current Role: Standby Software 3.36 9. Enter the set controller command to indicate the controller to be flashed: Example command and response, using the sample information in Step 8: MSA> SET CONTROLLER $1$GGA400. 10. Enter the flash firmware command to begin the update: Example command and response, using the sample information in Step 1: MSA> FLASH FIRMWARE MSAV686B272.BIN Sending Flash Command. Please wait. New firmware will be loaded when THIS_CONTROLLER is reset. NOTE: The MSA displays the message FIRMWARE FLASH STARTED when it starts the download and FIRMWARE FLASH DONE when the download is complete. 11. After the controller displays FIRMWARE FLASH DONE, do one of the following: • If you have one MSA with a single controller, the firmware update procedure is complete. Proceed to Step 12. • If you have one MSA with dual controllers, you must update the firmware on the second controller. Repeat Step 8 through Step 10to update the firmware on that controller. • If you have multiple MSAs, repeat Step 8 through Step 10 for each controller in each MSA. 12. Enter the following command to exit the update utility: MSA> EXIT 13. After all MSA controllers have been updated and the controller displays FIRMWARE FLASH DONE, power-cycle the MSA by doing the following: a. Remove power from the MSA. b. After a few moments, reapply power to the MSA. After the MSA completes its start up routine, the STARTUP COMPLETE message is displayed: 14. To verify that the firmware was updated, use the following commands: $ RUN SYS$$ETC:MSA_UTIL MSA> SHOW CONTROLLER/BRIEF A default controller is not set. All matching controllers displayed: 30 Updating the components
![](/manual_guide/products/hewlettpackard-storageworks-modular-smart-array-1000-hp-storageworks-10001500-modular-smart-array-firmware-updating-guide-370881002-2007-98e3844/30.png)