HP StorageWorks Modular Smart Array 1000 HP StorageWorks 1000/1500 Modular Sma - Page 20

Using the Support Software CD (HP-UX), HPSSCDxxx, <xx&gt, To update the Array Con

Page 20 highlights

HPSSCDxxx :\netware\hpsetup.nlm (Where HPSSCDxxx is the label of the MSA Support Software CD.) After a few moments, the driver installation screen is displayed. b. Follow the onscreen instructions to complete the driver installation. c. After the driver is installed, load the NetWare Configuration Utility by entering: NWCONFIG d. In the Configuration Options window, select NCF files Options, and then press Enter. e. Select the Edit STARTUP.NCF file, and then press Enter. f. At Specify a server boot path:, enter the path. The default path is: C:\NWSERVER g. Enter the following LOAD command for each HBA, using the appropriate slot number to indicate where the HBAs are inserted in the server: LOAD QL2300.HAM SLOT = /LUNS /ALLPATHS /PORTNAMES (Where represents the slot number.) h. Press F10 to save the changes, and then return through all previous menus. 5. Remove the MSA Support Software CD from the CD-ROM drive, and then restart your NetWare server. 6. Repeat the steps in this section on each NetWare server with access to the MSA. Using the Support Software CD (HP-UX) 1. With the HBAs installed in the server, power on the server, start your HP-UX operating system, and log on as a user with administrative rights. 2. Insert the MSA Support Software CD into the CD-ROM drive of the server, and then mount the CD-ROM. 3. Browse the contents of the CD to locate and read the readme.txt file, which includes notes and information about the CD. 4. To update the Array Configuration Utility-Command Line Interface (ACU-CLI): a. Navigate to the /HPUXACUCLI/HP-UX directory for your environment. b. List the contents of the directory and identify the ACU-CLI depot file for your environment. c. Copy the ACU-CLI depot file and its corresponding readme file to a temporary directory on the server. For example: # cp /cdrom/HPUXACUCLI/HP-UX/IA64/HPACUCLI_IA_v7.47-1.depot .tmp d. Install the ACU-CLI application using the swinstall command. For example: # swinstall -s /tmp/HPACUCLI_IA_v7.47-1.depot e. Remove the MSA Support Software CD from the CD-ROM drive, and then restart your HP-UX server. f. Repeat the steps in this section on each HP-UX server with access to the MSA. 20 Updating the components

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40

HPSSCDxxx
:\netware\hpsetup.nlm
(Where
HPSSCDxxx
is the label of the MSA Support Software CD.)
After a few moments, the driver installation screen is displayed.
b.
Follow the onscreen instructions to complete the driver installation.
c.
After the driver is installed, load the NetWare Con
guration Utility by entering:
NWCONFIG
d.
In the Con
guration Options window, select
NCF
les Options
, and then press Enter.
e.
Select the
Edit STARTUP.NCF
le, and then press Enter.
f.
At
Specify a server boot path:
, enter the path.
The default path is:
C:\NWSERVER
g.
Enter the following
LOAD
command for each HBA, using the appropriate slot number to indicate
where the HBAs are inserted in the server:
LOAD QL2300.HAM SLOT =
<XX>
/LUNS /ALLPATHS /PORTNAMES
(Where
<xx>
represents the slot number.)
h.
Press
F10
to save the changes, and then return through all previous menus.
5.
Remove the MSA Support Software CD from the CD-ROM drive, and then restart your NetWare
server.
6.
Repeat the steps in this section on each NetWare server with access to the MSA.
Using the Support Software CD (HP-UX)
1.
With the HBAs installed in the server, power on the server, start your HP-UX operating system,
and log on as a user with administrative rights.
2.
Insert the MSA Support Software CD into the CD-ROM drive of the server, and then mount the
CD-ROM.
3.
Browse the contents of the CD to locate and read the
readme.txt
le, which includes notes and
information about the CD.
4.
To update the Array Con
guration Utility-Command Line Interface (ACU-CLI):
a.
Navigate to the /HPUXACUCLI/HP-UX directory for your environment.
b.
List the contents of the directory and identify the ACU-CLI depot
le for your environment.
c.
Copy the ACU-CLI depot
le and its corresponding readme
le to a temporary directory on
the server. For example:
# cp /cdrom/HPUXACUCLI/HP-UX/IA64/HPACUCLI_IA_v7.47–1.depot .tmp
d.
Install the ACU-CLI application using the
swinstall
command. For example:
# swinstall —s /tmp/HPACUCLI_IA_v7.47–1.depot
e.
Remove the MSA Support Software CD from the CD-ROM drive, and then restart your HP-UX
server.
f.
Repeat the steps in this section on each HP-UX server with access to the MSA.
20
Updating the components