HP StorageWorks Modular Smart Array 1000 HP StorageWorks 1000/1500 Modular Sma - Page 18

Insert the HP StorageWorks Modular Smart Array 1000/1500 Support Software CD

Page 18 highlights

Step Description (continued) Check 8 Insert the HP StorageWorks Modular Smart Array 1000/1500 Support Software CD F and install the required applications and drivers from the CD: • Qlogic/Emulex HBA driver (restart the server if required) • Array Configuration Utility (ACU) software • (Optional) Array Configuration Utility CLI (ACUCLI) software • (Optional) Array Diagnostics Utility (ADU) software • (Optional) HP MPIO Full-Featured DSM for Windows (restart the server if required) • (Optional) HP MPIO DSM Manager 9 Remove the HP StorageWorks Modular Smart Array 1000/1500 Support Software F CD from the CD-ROM drive. 10 (For systems with HP Secure Path MPIO software only) F • Enable HP Secure Path services and drivers: • From the server console desktop, select Start>Run. • In the Run window, enter devmgmt.msc and then click OK to open the Device Manager Utility. • Select SCSI and RAID controllers, right-click the Compaq Secure Path Disk Bus device, and then select Enable. • Close the Device Manager Utility. • From the server console desktop, select Start>Run. • In the Run window, enter services.msc and then click OK to open the Services Utility. • In the right pane, double-click Compaq HS_ Service. • Change the Startup type from Disabled to Automatic. • Click OK to close the window. • In the right pane, double-click Secure Path Agent. • Change the Startup type from Disabled to Automatic. • Click OK to close the window. • If HP Secure Path Manager software is installed, double-click Element Manager for Secure Path in the right pane to open the Element Manager for Secure Path Properties window. • Change the Startup type from Disabled to Automatic. • Click OK to close the window. • Close the Services Utility. 11 Shut down the server node. F Note: Skip this step if this is the only node running in the cluster. 12 Go to migration step 1 to migrate all other server nodes within the F cluster. 13 Using the MSA1000/1500 firmware updating guide, upgrade the HP StorageWorks F MSA1000/1500 controller firmware from active/passive to active/active. 14 When the MSA firmware upgrade is complete, shut down the server node. F 15 Notify all system units connected to the MSA disk array that the disk array will F temporarily be offline. 17 Restart the disk array. F 18 Notify all system units connected to the MSA disk array that the array is back online. F 18 Migrating single-path cluster systems

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34

18
Migrating single-path cluster systems
8
Insert the HP StorageWorks Modular Smart Array 1000/1500 Support Software CD
and install the required applications and drivers from the CD:
Qlogic/Emulex HBA driver (restart the server if required)
Array Configuration Utility (ACU) software
(Optional) Array Configuration Utility CLI (ACUCLI) software
(Optional) Array Diagnostics Utility (ADU) software
(Optional) HP MPIO Full-Featured DSM for Windows (restart the server if required)
(Optional) HP MPIO DSM Manager
9
Remove the HP StorageWorks Modular Smart Array 1000/1500 Support Software
CD from the CD-ROM drive.
10
(For systems with HP Secure Path MPIO software only)
Enable HP Secure Path services and drivers:
From the server console desktop, select
Start>Run
.
In the Run window, enter
devmgmt.msc
and then click
OK
to open the Device
Manager Utility.
Select
SCSI and RAID controllers
, right-click the
Compaq Secure Path Disk Bus
device
, and then select
Enable
.
Close the Device Manager Utility.
From the server console desktop, select
Start>Run
.
In the Run window, enter
services.msc
and then click
OK
to open the
Services Utility.
In the right pane, double-click
Compaq HS_ Service
.
Change the Startup type from
Disabled
to
Automatic
.
Click
OK
to close the window.
In the right pane, double-click
Secure Path Agent
.
Change the Startup type from
Disabled
to
Automatic
.
Click
OK
to close the window.
If HP Secure Path Manager software is installed, double-click
Element Manager
for Secure Path
in the right pane to open the Element Manager for Secure Path
Properties window.
Change the Startup type from
Disabled
to
Automatic
.
Click
OK
to close the window.
Close the Services Utility.
11
Shut down the server node.
Note
:
Skip this step if this is the only node running in the cluster.
12
Go to migration step 1 to migrate all other server nodes within the
cluster.
13
Using the MSA1000/1500 firmware updating guide, upgrade the HP StorageWorks
MSA1000/1500 controller firmware from active/passive to active/active.
14
When the MSA firmware upgrade is complete, shut down the server node.
15
Notify all system units connected to the MSA disk array that the disk array will
temporarily be offline.
17
Restart the disk array.
18
Notify all system units connected to the MSA disk array that the array is back online.
Step
Description
(continued)
Check