appropriate number of HP MSA Volume SCSI Disk Device are present.

Page 32 highlights

Step Description (continued) Check 4 Verify the additional device drivers from the secondary path are installed correctly F within Device Manager: • From the server console desktop, select Start>Run. • In the Run window, enter devmgmt.msc and then click OK to open the Device Manager Utility. • From the main menu, select View>Show hidden devices. • Right-click the Disk Drives icon, and then select Scan for hardware changes. • Select Disk Drives to verify that all disks are functioning properly and that the appropriate number of HP MSA Volume SCSI Disk Device are present. (For example, if four LUNs are presented from the MSA disk array, eight HP MSA Volume SCSI disk devices should be present.) • Select System Devices to verify that the appropriate number of StorageWorks MSA1000/1500 devices are installed. (For multi-path environments, there should be two StorageWorks MSA1000/1500 devices for every MSA1000/1500 disk array connected.) • For each StorageWorks MSA1000/1500 device present, verify that the correct driver versions are installed: • Double-click the StorageWorks MSA 1000/1500 device to open the StorageWorks MSA1000/1500 Properties window. • Click the Driver tab, and then click Driver Details to open the Driver File Details window. • Verify that the CPQFCAC.SYS driver version is 5.30.0.32 or later. • Click OK to close the Driver File Details window. • Click OK to close the StorageWorks MSA1000/1500 Properties window. • Close the Device Manager Utility. 5 Enable network connections on the system: F • From the server console desktop, select Start>Run. • In the Run window, enter ncpa.cpl and then click OK to open the Network (and Dial-up) Connections Utility. • Right-click each network connection going to the public network, and then select Enable. • Close the Network (and Dial-up) Connections Utility. 6 Enable the cluster service: F • From the server console desktop, select Start>Run. • In the Run window, enter services.msc and then click OK to open the Services Utility. • In the right pane, double-click Cluster Service to open the Cluster Service Properties window. • Change the Startup type from Disabled to Automatic. • Click OK to close the window. • Close the Services Utility. 7 Restart the system unit. F 32 Migrating multi-path cluster systems

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34

32
Migrating multi-path cluster systems
4
Verify the additional device drivers from the secondary path are installed correctly
within Device Manager:
From the server console desktop, select
Start>Run
.
In the Run window, enter
devmgmt.msc
and then click
OK
to open the Device
Manager Utility.
From the main menu, select
View>Show hidden devices
.
Right-click the
Disk Drives
icon, and then select
Scan for hardware changes
.
Select
Disk Drives
to verify that all disks are functioning properly and that the
appropriate number of HP MSA Volume SCSI Disk Device are present. (For
example, if four LUNs are presented from the MSA disk array, eight HP MSA
Volume SCSI disk devices should be present.)
Select
System Devices
to verify that the appropriate number of StorageWorks
MSA1000/1500 devices are installed. (For multi-path environments, there should
be two StorageWorks MSA1000/1500 devices for every MSA1000/1500 disk
array connected.)
For each StorageWorks MSA1000/1500 device present, verify that the correct
driver versions are installed:
Double-click the
StorageWorks MSA 1000/1500
device to open the
StorageWorks MSA1000/1500 Properties window.
Click the
Driver
tab, and then click
Driver
Details
to open the Driver File Details
window.
Verify that the CPQFCAC.SYS driver version is 5.30.0.32 or later.
Click
OK
to close the Driver File Details window.
Click
OK
to close the StorageWorks MSA1000/1500 Properties window.
Close the Device Manager Utility.
5
Enable network connections on the system:
From the server console desktop, select
Start>Run
.
In the Run window, enter
ncpa.cpl
and then click
OK
to open the Network (and
Dial-up) Connections Utility.
Right-click each network connection going to the
public
network, and then select
Enable
.
Close the Network (and Dial-up) Connections Utility.
6
Enable the cluster service:
From the server console desktop, select
Start>Run
.
In the Run window, enter
services.msc
and then click
OK
to open the Services
Utility.
In the right pane, double-click
Cluster Service
to open the Cluster Service Properties
window.
Change the Startup type from
Disabled
to
Automatic
.
Click
OK
to close the window.
Close the Services Utility.
7
Restart the system unit.
Step
Description
(continued)
Check