HP StorageWorks Modular Smart Array 1000 HP StorageWorks 1000/1500 Modular Sma - Page 20
Start>Run, Computer Management>Storage>HP MPIO DSM Manager, Description, continued, Check
View all HP StorageWorks Modular Smart Array 1000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 20 highlights
Step Description (continued) Check 6 Verify Cluster functionality: F • From the server console desktop, select Start>Run. • In the Run window, enter cluadmin. and then click OK to open the Cluster Administrator Utility. • In the right pane, right-click each of the cluster groups and select Move to move each group to this server node. Note: Skip this step if this is the only node running in the cluster. • Verify that each cluster group is online and is owned by this server node. • Close the Cluster Administrator Utility. 7 Verify that the HP MPIO DSM Manager (if installed) can access the MSA disk array: F • From the server console desktop, select Start>Run. • In the Run window, enter compmgmt.msc and then click OK to open the Computer Management Utility. • In the left pane, click Computer Management>Storage>HP MPIO DSM Manager. • Verify that the HP MPIO DSM Manager can locate and access the updated MSA disk array. • Close the Computer Management window. 8 Verify that all standalone and cluster-aware applications are functioning properly. F 9 Verify that users and applications can access MSA disk array. F 10 Go to post-migration step 1 to repeat the post-migration procedures F on all other server nodes within the cluster. 11 Review the MSA1000/1500 active/active controllers best practices guide to F maximize system performance and high availability. 20 Migrating single-path cluster systems