HP Surestore Disk Array FC60 HP SureStore E Disk Array 12H User's and Service - Page 159
No Disk Drives, Space To Start
View all HP Surestore Disk Array FC60 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 159 highlights
Troubleshooting Troubleshooting Event Code Descriptions Event Number (DEC/hex) Event Name Event Predictive Suspected Logged Maintenance Components Implication Description 135/0x87 No Disk Drives Found During Initialization Y Ignore - Operator activity None During startup no disk drives were present. A new disk set was created with no members. 136/0x88 Insufficient Space During Rebuild Y Ignore - See None accompanying errors. There is insufficient disk space for migrating data during a rebuild. This is a controller error, although the disk array may still support some I/Os without adding disks. 137/0x89 Rebuild Started Y Ignore - See None accompanying errors. A rebuild has been started either automatically or by command. 138/0x8a Rebuild Complete Y Ignore None A rebuild has completed successfully. 139/0x8b Insufficient Space To Start Rebuild Y Ignore - See None accompanying errors A rebuild was not started due to insufficient disk space. This event is most likely to occur when Active Hot Spare is not enabled. To create the necessary disk space, add a disk or delete a LUN. 140/0x8c Rebuild Failed Y Ignore - See None accompanying errors Rebuild has failed to complete due to multiple disk failures or a controller failure. Previous messages in the log should indicate whether or not there have been multiple disk failures. 159