Troubleshooting Troubleshooting Event Code Descriptions Event Number (DEC/hex) Event Name Event Predictive Suspected Logged Maintenance Components Implication Description 203/0xcb Replace Batteries Y Single Batteries The batteries have failed a Occurrence Controller discharge test or have dropped below an acceptable voltage level. Both batteries should be replaced. 204/0xcc Cache Shrink Attempted After Shutdown Warning Y Ignore - see None errors during shutdown The amount of cache on the controller has shrunk due to SIMM failure or removal. This happened with valid writes still in cache, and all the writes no longer fit in the reduced amount of cache. 205/0xcd Controller Failed Y Ignore if Controller corrected by reset or power cycle During power on, a bad controller was detected. This may result if the controller has difficulty establishing communication. Ignore if recovered by power cycle or reset. 206/0xce SIMM Failed Y Single SIMM Occurrence Controller A SIMM was discovered to be bad during power on. 207/0xcf Extended Drive Installation Event Y Ignore unless Disk Drive An internal SCSI channel is no operator Controller being held reset longer than activity Internal SCSI expected. Typically caused by Bus a partially-installed drive module, a failing drive module, a failing controller, or a bent pin on a connector. 177